4.1.5 Displaying the history data

The history data can be displayed by inputting the machine manufacturer password.
The following items are displayed as the history data.
• Alarm history
• Warning history
• Signal history
• Key history
(1) History data format
(a) Alarm history
(b) Warning history
(c) Signal history
(d) Key history
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
Symbol: E
Number of history items: 250
Format: [History type (E)] [Date] [Time] [Alarm No.] [Parameter data 1] [Parameter data 2]
Symbol: W
Number of history items: 170
Format: [History type (W)] [Date] [Time] [Warning No.] [Parameter data 1] [Parameter data 2]
Symbol: S
Number of history items: 426
Format: [History type (S)] [Date] [Time] [Device name] [ON/OFF (data for R239)] [Signal name]
Symbol: K
Number of history items: 426
Format: [History type (K)] [Date] [Time] [NC key code (hexadecimal display] [Key name]
search engine
4. Edit Screens
(or [Power signal])
I – 241
(or [Power signal])

Advertisement