3.9.1 Carrying out tool length measurement
(1) Carrying out tool length measurement
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
1)
Turn ON the measurement
switch (Y720).
2)
Press the menu
.
T-leng measure
3)
Contact the measurement
tool against the sensor, using
manual feed and manual
handle feed. Stop the feed
when the tool contacts the
sensor.
4)
The cursor moves to the
compensation No. that sets
the measurement results.
12
Offset No.
INPUT
The cursor display position
differs depending on the
measurement mode.
Tool length measurement
mode: Length dimension
Tool radius measurement
mode: Radius dimension
5)
Press the menu
Offset write
(Note 1) The measurement values are not written if the cursor is in a position other than
"Length" or "Radius".
(Note 2) The axis returns and stops after contacting the sensor, but be careful that the axis
does not move after that. If the axis moves after contacting the sensor, the coordinate
value that was actually moved will be displayed in the measurement values counter,
and the skip position will not be held.
6)
Turn OFF the measurement
switch to finish measuring.
search engine
3. Setup Screens
The message "On meas 0" appears.
The menu is highlighted, and the tool length
measurement starts. The measurement values are
displayed in "Meas value" during the measurement.
The menu
T-leng measure
after the power is turned ON.
When the measurement tool contacts the sensor, the
skip position displayed in the measurement values
counter.
The cursor appears.
Tool offset
Ofset No. Length
Length wear
12
-123456.678
-123456.678 -123456.678 -123456.678
13 -123456.678 -123456.678 -123456.678 -123456.678
14 -123456.678 -123456.678 -123456.678 -123456.678
15 -123456.678 -123456.678 -123456.678 -123456.678
16 -123456.678 -123456.678 -123456.678 -123456.678
17 -123456.678 -123456.678 -123456.678 -123456.678
The measurement values are written as a tool offset
.
amount.
The wear amount is cleared to "0" for the tool offset
type II .
The screen returns to the main menu.
The message "On meas 0" disappears.