Displaying In Group Units (Tool Life (Grp) Screen) - Mitsubishi Electric MELDAS 600M Series Instruction Manual

Table of Contents

Advertisement

3.6.2 Displaying in group units (Tool life (grp) screen)

The tool life management data of a random group is set and displayed. If the registered tools cannot be
displayed on one screen, scroll the screen using the
(1) Display items
Display item
Group No.
Tool No.
ST
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
This is the number of the tool on which the tool life management
is being carried out.
These numbers are only displayed when displaying by group
units.
This is the number corresponding to each tool. Depending on
the specification configuration, up to 1000 tools can be
registered.
Tool status
Machine manufacturer release
Tool status
0 : Unused tool
Normally set to "0" when the tool is replaced with a new
tool.
1 : Used tool
This becomes "1" when the cutting actually starts.
2 : Normal life tool
This becomes "2" when the usage data (usage time and
number of uses) exceeds the life data.
3 : Tool abnormality 1 tool
4 : Tool abnormality 2 tool
(Note) Item 3 and 4 differ depending on the machine
manufacturer specifications.
search engine
3. Setup Screens
or
key.
Details
I – 179
Setting range
1 to 99999999
1 to 99999999

Advertisement