5.7 Condition Setting screen (V Anlyz condition screen)

The various conditions such as sampling data and trigger data are set on this screen.
1. Channel 1
setting area
2. Channel 2
setting area
(1) Display items
1. Channel 1
setting area
2. Channel 2
setting area
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
V Anlyz condition
Ch1
Data
V-scale/div
Base line
Offset
Samp valid
Ch2
Data
V-scale/div
Base line
Offset
Samp valid
RDY:MEM :
Area
Data
change
type
Display item
The various data for channel 1 and channel 2 are set.
"Data" can be selected from the menu. For the conditions other than
"Data", select the item with the cursor, and input the value.
When the Next Page key is pressed, the setting area will change from
Channel 1 and 2 to Channel 3 and 4. The data for up to ten channels
can be set.
Data
Vert scale/div : This is the vertical axis scale. Set how many sample
Base line
Offset
Samp valid
search engine
5. Diagnosis Screens
Monitor
X/Position command
Sample rate
10000
H-scale
0
Stop trigger
0
Stop level
0
Delay time
X/Position command
10000
0
0
0
Clear
: Set the type of data to be sampled and the axis name.
data items corresponds to one scale.
(Setting range: 0 to 10000000)
: Designate at which the scale the vertical axis' zero is
positioned. (Setting range: − 8 to 8)
: Set the value to be added as the offset value to the
sample data. (Setting range: − 10000000 to 10000000)
: Set whether channel sampling is valid or not.
(0: Invalid, 1: Valid)