Setting The S, M, T And B Current Modal Values - Mitsubishi Electric MELDAS 600M Series Instruction Manual

Table of Contents

Advertisement

(2) Automatic return to restart position
If the "#320020 Auto restart valid" parameter on the Control Parameter screen is turned ON and
cycle start is executed, all axes simultaneously return to the restart position with dry run. After return
is completed, machining restarts.
(Note 1) In the manual or MDI mode, remove the axis to a position where the tool does not
(Note 2) Even if the "Auto restart valid" parameter is ON, the axis can be returned to the restart
(Note 3) If the axis is returned to the restart position manually once and then is moved from that
(Note 4) If the manual mode is entered and the axis is moved during the automatic restart

2.5.5 Setting the S, M, T and B current modal values

After restart search is completed, if the menu key
and B used in the machining program appear. After restart search is completed, the S, M, T and B
function settings can be made manually before executing reset or cycle start.
The maximum number of displayed codes are 16 for M, three for S, three for T and three for B. If there
are many codes used for machining, the recently used codes are displayed.
To designate the current modal value of each command, move the cursor to select the value, and press
the
INPUT
Codes that are not displayed cannot be commanded on this screen. Execute the manual value command
on the Position Display 1 or 2 screen.
Refer to "1.5.1 Setting a manual value command" for details on the manual value command.
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
2. Monitor (Operation) Screens
contact the workpiece, and then execute cycle start.
position manually.
restart position, the axis does not return to the restart position even if automatic return to
restart position is executed.
position return, the return position after restarting will be shifted by the amount the axis
was moved manually. In this case, the restart remaining distance will not be 0 when
automatic restart position return is completed.
key.
search engine
is pressed, the modal values of S, M, T
MSTB history
I – 60

Advertisement

Table of Contents
loading

Table of Contents