(2) Notes for continuous sampling
1) If there are no trigger conditions and another screen is displayed during continuous sampling,
2) If there is a trigger condition and another screen is displayed during continuous sampling, the
3) Only data handled as Long type data can be registered as an NC file on the V Anlyz condition
4) The sampling buffer is a 3072-point ring buffer (1536 points for 2-channel synchronization,
5) The auxiliary axis data can be sampled when the parameter "110067 AUX axis nos" is set to
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
the sampling will end at the point the other screen was displayed. Thus, when the Visual
analyzer screen is returned to from the other screen, the waveform will be cleared and the
sampling will be stopped.
sampling will not end. However, the waveform will not appear until the sampling is completed
after the trigger conditions are established.
screen. If data that cannot be handled as a Long type is set, a "Setting error" will occur when
the Continu samplng menu is selected.
1024 points for 3-channel synchronization). Thus, the waveform display will rely on these
number of points. The waveform will be cut off during continuous sampling because of this.
more than one.