Mitsubishi Electric MELDAS 600M Series Instruction Manual page 457

Table of Contents

Advertisement

2.9 Measurement-related (workpiece, rotation) operation messages
TLM switch OFF
Can't take-in skip posn
Can't write coordinates
data
Can't write rotation
parameter
Can't calculate center &
angle for rot
Sensor take in not
possible
Input 0 to coord center
& angle for rot
Can't write
compensation data
2.10 Operation messages related to pallet program registration
Pallet running
APC executing
Setting error
Downloaded from
ManualsNet.com
Appendix 2. Operation Messages
Message
• Measurement was attempted when the TLM switch was OFF.
• Could not retrieve the skip position.
→ Check the following:
< When measuring the workpiece >
1. Is the name of the axis to be measured designated in the basic axis
(I, J, K)?
2. Is the axis that executed the axis movement a measurement axis?
< When measuring the rotation >
1. Is the name of the axis to be measured designated in the coordinate
rotation plane (horizontal axis, vertical axis)?
2. Is the axis that executed the axis movement a measurement axis?
• Could not obtain the measured axis No.
• The measured angle was illegal.
• Could not write into the coordinate system offset.
→ Measure again.
• Could not write the measurement results to the machining parameters.
• The three points required for measurement have not been taken in.
• Retrieval of the center shift amount failed.
• Retrieval of the sensor radius failed.
• The center and angle measurement failed.
→ Measure three points before writing the coordinate system.
• Could not retrieve the position measured with the touch sensor.
→ Measure again.
• The center and angle are not set to "0".
→ Set the parameters [Coord rot center] and [Coord rotation angle] to
"0".
• The cursor position and the cell for writing the compensation amount
(length dimension, radius dimension) do not match.
→ Match the cursor position with the cell for writing the compensation
amount.
Message
• The program for the pallet in the machine was registered.
• The program was registered during APC (automatic pallet changer)
execution.
• Data exceeding the setting range was set.
search engine
CHAPTER 4 APPENDICES
IV – 15
Details
Details

Advertisement

Table of Contents
loading