(2) Menus
G54-G59
G54.1 P_
Downloaded from
ManualsNet.com
CHAPTER 1 SCREEN OPERATIONS
Menu
This puts the machine in a state to start surface
Surface
measurement.
start
This puts the machine in a state to start hole
measurement. (The cursor moves to the point A
Hole-M
measurement counter.)
start
This puts the machine in a state to start width
measurement. (The cursor moves to the point A
Width
measurement counter.)
measure
The results calculated from the measurement counter
are set in the displayed workpiece coordinate offset.
Only the axis for which a value is displayed in the
Coord
measurement counter can be set.
write
(Note) If the workpiece coordinate system to be set is
G54 to G59, the local coordinate offset value
will be zero. (Only for the measured axis.)
This selects the number of the coordinate system to be
displayed from the submenu (G54 to G59). When the
number is selected, that workpiece coordinate system
Coord
offset data is displayed.
Note that the cursor does not appear, and setting is not
possible.
(Setting is carried out on the
When the P No. is input, this displays the expansion
Coord
workpiece coordinates (G54.1 Pn) offset data in the
counter display area.
(Setting is carried out on the
This displays the offset data of the external coordinate
Coord
system.
EXT
(Setting is carried out on the
In simple measurement (measurement without using a
touch sensor), the sensor signal is pseudo-generated,
SkipPos
and the skip position is read in. When this menu is
take in
pressed, the machine position of the axis that moved
last (1 axis or 2 axis) is read in and displayed in the
measurement counter. (Note)
Random values can be input in each data item of M and
Manual
T on the screen.
value
When the numeric value is input, the selected M and T
functions are executed.
This can be selected when there are seven or more
display axes for the selected system . The axes
Next
displayed are changed between the 1st to 6th axes and
axis
the 7th to 8th axes.
(This is used when there are seven to eight axes in one
system.)
search engine
3. Setup Screens
Details
menu.)
Coord write
menu.)
Coord write
menu.) (Note)
Coord write
I – 188
Type
Reference
(3) Details of the
"Measurement
C
counter" and
"Guide drawing"
display areas
3.7.1 Carrying out
C
surface
measurement
3.7.2 Carrying out
hole
measurement
3.7.3 Carrying out
C
width
measurement
C
3.2.1 Setting the
coordinate system
offset data
C
3.2 Coordinate
System Offset
A
screen
C
B
1.5.1 Setting a
manual value
A
command
1.5.4 Changing
the display axis
C