Error No.
PR0037
PR0038
PR0039
PR0040
PR0041
PR0042
PR0043
PR0050
PR0060
PR0061
PR0062
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 3. Alarm Messages
Message
Zero has been designated for a
Label and N number
program number or sequence
zero
number.
"/n" has been issued even though
No additional Op
there are no optional block skip
block skip
addition specifications.
There was no EOB code at the
No EOB
end of the program block, and an
EOR (%) code resulted.
More address than those that can
Unused address
be simultaneously commanded in
exists
one block were commanded.
Number of simultaneous
commands in one block:
M = maximum 4 commands,
other than M = 1
Multiple G codes were
Overlap G code
commanded in the same group.
exists
Meaningless H code An H command other than H0
was commanded independently
during tool length offset.
The end point coordinate
No end point
command has not been issued for
operation in arc
the R-designated arc.
A command has been issued with
No inch/mm spec.
a G code for inch/mm conversion
even though there is no inch/mm
conversion G code specifications.
The commanded movement
Compensation
distance is excessive. (It exceeds
length over
31
2
)
The G60 command has been
No 1-direction
issued even though there is no
positioning spec.
uni-direction positioning
specifications.
The feedrate command has not
No F command
been entered.
This alarm occurs because the
movement modal command is set
to G01 when the power is
switched ON, and so movement
will be based on the G1
command, provided that a
movement command is issued,
even without G01 having been
designated in the program.
search engine
Details
• The program numbers are
designated across a range from
1 to 99999999.
• The sequence numbers are
designated across a range from
1 to 99999.
• Check the specifications.
• Use an EOB code at the end of
the program block.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Check the specifications.
• Reconsider the program.
• Check the specifications.
• Change the G60 program
command to G00.
• Designate an F command in the
program.