Measurement Tools Parametrization Mode [Oxm] - Baumer OX200 Operating Manual

Smart profile sensors
Hide thumbs Also See for OX200:
Table of Contents

Advertisement

9
|
Web interface operation
9.3

Measurement Tools Parametrization mode [OXM]

In Measurement Tools Parametrization mode you can allocate measurement tools to the
sensor and set the properties of the individual measurement tools. A measurement tool is a
function that is predefined in the sensor and which can be used to generate measurement val-
ues such as height, width or angle, based on the profile data.
Ill. 39: Web interface – Measurement Tools Parametrization mode
The order of the measurement tools in the Measurement Tools window corresponds to the or-
der of the selected measurement value in the measurement results array. Click the 3 dashes of
the respective measurement tool to change its position or name or to delete the measurement
tool.
Measurement tool vs. auxiliary tool
Measurement tools use the profile as input. Auxiliary tools use the output of a measurement tool
as input. For an auxiliary tool, the input must be defined before a measurement value can be
displayed. If the input has not been defined or if a measurement value at the input is invalid,
NaN (Not a Number) is the output. Due to the fact that the measuring tools and the auxiliary
tools can also display negative numbers, a number is not possible as error code.
ROI (Region of Interest)
ROI (Region of Interest) is the region where the profile points are included in the evaluation
(shown in green on the web interface). You can freely select the ROI (on the web interface with
the help of the sliders or the input fields).
Blind region
Blind regions (shown in grey on the web interface) are the regions outside the ROI. Profile
points and measurement values inside the blind region are ignored in the evaluation. You can
freely select the blind regions (on the web interface with the help of the sliders or the input
fields).
96
Operating Manual
Baumer
OX200 | V2

Advertisement