Using an auxiliary plate
To compensate for irregularities in the reference surface, an auxiliary plate can be used for the
teach-in process. The reference plate should be as smooth and even as possible and must fulfil
the minimum length of the reference surface L
the sensor, L
condition is the same as for teaching in the Flex Mount. Make sure that the auxiliary plate is
parallel to the reference surface below. As long as the auxiliary plate is within the measurement
field of the sensor you can freely select its thickness. You can then deduct the thickness via the
web interface (see
Ill. 37: OX200 – Minimum length of the reference surface L
OX200 | V2
is at approx. 50 % of the field of view depth at the reference distance. The
R, min
Flex Mount: Moving the reference surface
Operating Manual
. Depending on the measurement range of
R, min
[} 94]).
R, min
Web interface operation
|
9