Measurement frequency, measurement repeat time and response time
A complete measurement cycle of the sensor consists of the following steps:
1. Exposure and read out
2. Calculation
3. Output of the measurement results
To increase the measurement speed, process steps are executed in parallel. Two situations are
illustrated below: Measurement rate limited by the exposure time (first figure) and measurement
rate limited by the calculation time (second figure):
Single shot
mode (trigger)
Exposure &
read out
Calculation
Measurement result
output
Ill. 6: OX200 – Measurement rate limited by the exposure time
Single shot
mode (trigger)
Exposure &
read out
Calculation
Measurement result
output
Ill. 7: OX200 – Measurement rate limited by the calculation time
OX200 | V2
Earliest possible
trigger pulse
Depending on:
- Exposure time
- Field of view
Measurement
repeat time
Depending on
the measurement
tool
Response time
Earliest possible
trigger pulse
Depending on:
- Exposure time
- Field of view
Measurement
repeat time
Response time
Operating Manual
Depending on the
measurement tool
Description
|
3
Time
Time
13