3
|
Description
Address
Address
401
(1 byte)
28
Data element
Data type
Measured value
Float32
4
Measured value
Float32
5
Measured value
Float32
6
Measured value
Float32
7
Measurement
Float32
rate
Time stamp (s) UInt32
Time stamp
UInt32
(µs)
Encoder value UInt16
Data element
Active Parameter Setup Number. UInt8
Operating Manual
Access Offset
Description
7
Low 2 Bytes
8
High 2 Bytes
Measured value parametrised in
advance on the web interface.
9
Low 2 Bytes
10
High 2 Bytes
Measured value parametrised in
advance on the web interface.
11
Low 2 Bytes
12
High 2 Bytes
Measured value parametrised in
advance on the web interface.
13
Low 2 Bytes
14
High 2 Bytes
Measured value parametrised in
advance on the web interface.
15
Low 2 Bytes
16
High 2 Bytes
Measurement rate
17
Low 2 Bytes
18
High 2 Bytes
Value of the time stamp (s) of the
most recent measured values.
19
Low 2 Bytes
20
High 2 Bytes
Value of the time stamp (µs) of
the most recent measured values.
21
Low 2 Bytes
22
High 2 Bytes
23
Encoder value of the connected
encoder.
Data type Access Offset
Read
Baumer
Description
1
OX200 | V2
Need help?