Technical Data; General Technical Data; Operating And Storage Conditions - Edwards iXM Series Instruction Manual

Dry pump system
Table of Contents

Advertisement

3. Technical data

3.1 General technical data

Table 1 General technical data
Characteristics
Dimensions (L x W x H)
Mass (not including
packaging)
Noise level (at ultimate)
Vibration test limit at in-
let
Initial force to push the
pump
Sustained force to push
the pump
Warm-up time to nomi-
nal pumping perform-
ance
Performance
Typical peak pumping
speed (no gas purge/
cold pump)
Average ultimate pressure
No gas purge
At 44 slpm purge flow
At 96 slpm purge flow
Ultimate pressure test limit
▪ No gas purge
▪ At 44 slpm purge
flow
▪ At 96 slpm purge
flow
Connections
Pump inlet flange
Exhaust gas outlet

3.2 Operating and storage conditions

M56635880_D
M56635880_D - Technical data
Units
3000
1000 x
517
mm
x 965
kg
570
dB (A)
< 65
-1
mm s
kg
kg
hours
0.75
3
-1
2800
m
h
mbar
0.001
mbar
0.0015
mbar
0.003
mbar
mbar
0.005
mbar
0.01
ISO200
ISO100
NW40
Page 13
1200
1200T
695 x 286 x 704
245
< 1.5
< 20.0
< 10.0
3
1030
0.005
0.02
0.005
0.01
0.05
-
ISO100
NW25
NW25
600
1200TX
600T
695 x 286
< 63
0.75
3 (T variant)
930
600
0.0015
-
-
-
ISO100
ISO100
NW25
NW25
10/2020 - ©Edwards Limited
200
200T
x
467
145
200
0.01
0.05
-
ISO63
NW25