Fault
Warning 63.13 - Sensor Fault
Cause
Sensor is faulty (short circuit)
Remedy
Contact us.
Fault
Warning 70.11 - DP E/C Temp High
Cause
Pump dry end cover temperature is high
Remedy
Check that the cooling water supply is connected and switched on. The supply must
be as per the specification given in
Fault
Warning 70.13 - Sensor missing
Cause
The dry pump end cover temperature sensor has possibly become disconnected
or failed
Remedy
Check that the sensor is installed and is correctly connected.
Fault
Warning 70.13 - Sensor Fault
Cause
Sensor is faulty (short circuit)
Remedy
Contact us.
Fault
Warning 71.13 - AC Sup Missing
Cause
The pump controller cannot communicate with the accessory module
1. Check that the accessory module is correctly connected to the pump and
Remedy
then cycle the power to the pump.
2. If this warning continues, contact us.
Fault
Warning 84.11 - Exh Temp High
Cause
The exhaust pipe temperature is too high.
Remedy
Contact us.
Fault
Warning 84.13 - Sensor missing
Cause
The exhaust pipe temperature sensor has possibly become disconnected or
failed.
Remedy
Contact us.
Fault
Warning 84.13 - Sensor Fault
Cause
Sensor is faulty (short circuit)
Remedy
Contact us.
M56635880_D
M56635880_D - Fault finding
Cooling water data
Page 73
on page 21.