TECHNICAL DATA

2.1

STC-U specifications

Applicable pump
Applicable control unit
Input voltage
Allowable input voltage fluctuation
Total Input power
Input frequency
Input phase
leakage current
Main breaker specification
Pollution degree
Installation category
Allowable ambient
temperature
Storage temperature
Mass
Dimensions
*2
Housing
TMS unit setting temperature
Panel indication LED
*1
Specific control unit for STP-XA2703BV155/XA3203BV155.
*2
Irregular color or small scratches may appear on the housing in the metal plate processing of the manufacturing process.
This is no abnormality.
STC-U eTMS unit
with STP control unit
without STP control unit
Rated current
Ampere Interrupting Capacity (AIC)
Material
Surface treatment
TMS heater
TMS valve
POWER
VALVE1
VALVE2
STP-XA2703BV155
STP-XA3203BV155
*1
SCU-1600/1601
200 to 240V AC
± 10%
2300 VA maximum
800 VA maximum
50/60 ± 2Hz
Single phase
1.5 mA maximum
7.5 A
750 A (250 V AC、50/60 Hz)
2
0 to 40 °C (32 to 104 °F)
-25 to 55 °C (-13 to 131 °F)
3.5 kg
Refer to Figure 10
SPCC
Trivalent chromate
Refer to Instruction Manual
(B) Section 3.5,
"Specification of TMS unit".
(Red / Green LED)
(Green LED)
(Green LED)