Lubrication; Connect The System; Connect To The Vacuum And Exhaust System; Figure 8 Reduce The Effective System Footprint Ixm3000 - Edwards iXM Series Instruction Manual

Dry pump system
Table of Contents

Advertisement

Figure 8 Reduce the effective system footprint iXM3000

4.5 Lubrication

The pumping systems are given a charge of oil before leaving the factory. It is not
necessary to check and adjust the oil level.

4.6 Connect the system

4.6.1 Connect to the vacuum and exhaust system

WARNING: DANGEROUS SUBSTANCES
Risk of inhalation injury. Connect the exhaust to an applicable treatment plant to
prevent the discharge of dangerous gases or vapours to the surrounding atmosphere.
WARNING: HOT SURFACES
Risk of burns. Do not touch the pump exhaust or check valve while the pump is
running. The high temperatures of pump parts can cause harm. Let the pump cool
before you disconnect the pump.
WARNING: PRESSURISED PIPING
Risk of fire or explosion. Do not operate the system if the exhaust pipeline is blocked.
If the exhaust pipeline is blocked, the system can supply exhaust pipeline pressures
up to 10 bar (10 x 10
CAUTION: CONDENSATE DRAINAGE
Risk of damage to the equipment. Use a catchpot to prevent the drainage of
condensate back into the system. Condensate that drains back into the system can
damage the pump.
M56635880_D
M56635880_D - Installation
5
Pa).
Page 31
10/2020 - ©Edwards Limited

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents