Characteristics
Rated input supply current maximum load
(200 V a.c.)
Rated input supply current maximum load
(400 V a.c.)
Recommended branch circuit protection UL
(200 ‑ 230 V a.c. supply)
Recommended branch circuit protection UL
(380 ‑ 460 V a.c.)
Recommended mains conductor size (mini-
mum)
Mains connector
Note:
Install to local, national, and regional electrical requirements/codes.
Table 8 General electrical data
Description
Supply voltage 3-phase
Frequency range
Wiring configuration
Branch circuit protection requirement
Voltage tolerance range
Installation category
Input supply voltage unbalance
Short circuit current rating (when installed
with class T or class J fuses)
Second protective earth (ground) conductor
Typical earth leakage*
▪ for 200 - 230 V a.c. systems
M56635880_D
M56635880_D - Technical data
Units
A (rms)
A (rms)
A
A
2
mm
(Awg)
-
Units
V a.c.
Hz
kA
mA
Page 19
1200
3000
1200T
1200TX
26
26
14
14
35
35
20
20
6 (10)
6 (10)
Han® K
4/4-F
Rating
200 - 230 or 380 - 460 (see rating plate)
50/60
3 wire plus earth (ground)
Current rating, refer to
trical data
Fuse Class gG (IEC 60269), UL class T, class
J or class RK5, Bussmann type JJS or equiv-
alent I2t characteristic rated to 600 V
± 10%
II (IEC 60664)
Should not exceed 2% when assessed over
any one minute period
30
Must be installed with cross-sectional area
equal to phase conductor size, up to 16
2
mm
< 5
10/2020 - ©Edwards Limited
600
200
600T
200T
26
18
14
11
35
25
20
15
6 (10)
6 (10)
Han® 40A
Table: Pump elec-

Hide quick links: