Events; Pdt Events - Edwards iXM Series Instruction Manual

Dry pump system
Table of Contents

Advertisement

Sensor
Booster pump end cover temperature
▪ iXM3000
Dry pump motor thermal snap switch
▪ All variants
Booster pump motor thermal snap switch
▪ iXM3000
* T Xcede+ only.
Refer to
down conditions.
If the system has an unplanned shut down, make sure that the cause of the shut down is
identified and corrected before restarting. If in doubt, contact supplier.
Note:
The high temperature alarms on Edwards vacuum pumping systems are system
protection trips and should be considered as an abnormal running condition. If a system
has tripped due to any high temperature alarm the system should be examined and the
reason for the alarm identified. Once the fault has been corrected the system should be
left for a minimum of 30 minutes before attempting to restart.

8.4 Events

8.4.1 PDT Events

Table 37 Events
Warning message on PDT
Event 252.63 - Chassis short
Event 252.65 - Chassis short
Event 253.63 - Accessory oload
Event 254.63 - Bus oload
Event 255.63 - Accessory oload
Event 256.63 - 24 V oload
Event 257.63 - Front Port oload
82
Event 258.63 - USB V oload
Note:
Some of these warnings apply to pump sensors that are only present on some dry
pumping system variants.
Some of these warnings apply to accessories and can only be encountered if the
particular accessory is installed.
M56635880_D
M56635880_D - Fault finding
Alarm conditions
on page 79 for information about alarms and automatic shut
on page 82
on page 82
on page 82
on page 82
on page 83
Warning condition trig-
gered (°C)
100
-
-
Action message on PDT
on page 82
Check equipment newly connected
on page 82
on page
Page 81
Alarm condition triggered
(°C)
110
150
70
10/2020 - ©Edwards Limited