CDX1000 Chemical Dry Vacuum Pumps and
IDX1000 and IDX1300 Industrial Dry Vacuum Pumps
Description
CDX1000, 30 kW, 50 Hz, Flameproof with Integral Flame Arrestors
CDX1000, 40 h.p., 60 Hz, Flameproof with Integral Flame Arrestors
CDX1000, 30 kW, 50 Hz, Flameproof (without Flame Arrestors)
CDX1000, 40 h.p., 60 Hz, Flameproof (without Flame Arrestors)
IDX1000, 22 kW, 50 Hz, Safe Area
IDX1000, 30 h.p., 60 Hz, Safe Area
IDX1000, 30 kW, 50 Hz, Safe Area, Extended Performance
IDX1000, 40 h.p., 60 Hz, Safe Area, Extended Performance
IDX1300, 30 kW, DIN, Safe Area
IDX1300, 40 h.p., ANSI, Safe Area
Notes: The Item Numbers listed above are for bareshaft pumps without motors. However, this manual contains
general information on pump motors. For detailed information on the specific motor fitted to the pump,
refer to the Motor Instruction Manual (P600-74-000) supplied with the pump.
The CDX/IDX Pumping System Instruction Manual (P600-74-600) supplied with the system will define the
build specification of the pump; that is, the type of motor and any accessories fitted.
If the CDX pump is part of an ATEX system, an ATEX system instruction manual (P600-74-500) will be
supplied, which defines the installation, operation and maintenance requirements for ATEX compliance.
Instruction Manual
A708-01-880
Issue E Original
Item Number
A708-01-985
A708-11-985
A708-02-985
A708-12-985
A708-03-985
A708-13-985
A708-04-985
A708-14-985
A709-04-985
A709-14-985

Advertisement

Table of Contents
loading

Summary of Contents for Edwards CDX1000

  • Page 1 CDX1000 Chemical Dry Vacuum Pumps and IDX1000 and IDX1300 Industrial Dry Vacuum Pumps Description Item Number CDX1000, 30 kW, 50 Hz, Flameproof with Integral Flame Arrestors A708-01-985 CDX1000, 40 h.p., 60 Hz, Flameproof with Integral Flame Arrestors A708-11-985 CDX1000, 30 kW, 50 Hz, Flameproof (without Flame Arrestors) A708-02-985 CDX1000, 40 h.p., 60 Hz, Flameproof (without Flame Arrestors)
  • Page 2 The relevant technical documentation has been compiled in accordance with Annex VII Part B. In response to a reasoned request by the national authorities, Edwards Ltd undertakes to provide relevant information on the partly completed machinery (via email).
  • Page 3: Table Of Contents

    Connect the pump to earth (ground) ................35 3.12 Check the direction of pump rotation ................35 3.13 Connect the cooling water supply ..................36 © Edwards Limited 2013. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 4 Clean/change the air bleed filters IDX1300 only ..............67 5.17 Fault finding ......................67 Storage and disposal ................71 Storage ........................71 Page ii © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 5 Minimum Pump Operating Temperatures (°C) ..............40 Minimum Pump Operating Temperatures (°F) ..............41 Maintenance Plan .......................49 Fault finding ......................69 Spares and Maintenance Kits ..................74 © Edwards Limited 2013. All rights reserved. Page iii Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 6 A708-01-880 Issue E Associated publications Publication title Publication number Vacuum pump and vacuum system safety P400-40-100 Page iv © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 7: Introduction

    Introduction Scope and definitions This manual provides installation, operation and maintenance instructions for the Edwards CDX1000 chemical dry vacuum pumps and the IDX1000 and IDX1300 industrial dry vacuum pumps. The pump must be used as specified in this manual. Read this manual before installing and operating the pump.
  • Page 8: Description

    Each oil circuit is also fitted with a pressure switch (IDX) or transmitter (CDX) to protect against loss of oil supply. Page 2 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 9: Drive Coupling Operation

    Pumps that are suitable for pumping hazardous gases and vapours have a leak tightness specification of better than mbar l s. © Edwards Limited 2013. All rights reserved. Page 3 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 10: The Idx Pump (Sheet 1 Of 2)

    14. Mounting feet (4 off, box section) 30. Vent filter body top 32. Pressure switch One on each side of the pump Page 4 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 11 A708-01-880 Issue E Figure 1 - The IDX pump (Sheet 2 of 2) © Edwards Limited 2013. All rights reserved. Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 12: The Idx1300 Pump (Sheet 1 Of 2)

    14. Mounting feet (4 off, box section) 31. Air Bleed 15. Cooling water outlet 32. Pressure switch One on each side of the pump Page 6 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 13 A708-01-880 Issue E Figure 2 - The IDX1300 pump (Sheet 2 of 2) © Edwards Limited 2013. All rights reserved. Page 7 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 14: The Cdx Pump (Sheet 1 Of 2)

    CDX without integral flame arrestors is as 17. TCV (thermostatic control valve) shown in Figure One on each side of the pump Page 8 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 15 A708-01-880 Issue E Figure 3 - The CDX Pump (Sheet 2 of 2) © Edwards Limited 2013. All rights reserved. Page 9 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 16: Accessories

    IDX pumps are designed for Safe Area applications only. Do not use the IDX pump in hazardous areas, or pumping hazardous gases/dusts. Page 10 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 17: Abnormal Operation: Cdx And Idx Pumps

    Use of the pump in a potentially explosive external atmosphere, unless the pumping system is certified as compliant with ATEX Directive 94/9/EC (European Union only). © Edwards Limited 2013. All rights reserved. Page 11 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 18 A708-01-880 Issue E This page has been intentionally left blank. Page 12 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 19: Technical Data

    Typical continuous A-weighted sound pressure level at ultimate vacuum 82 dB(A) Consult Edwards for advice on operation of the pump in ambient temperatures below -5 °C (23 °F). † The pump must be heated to at least +5 °C before starting.
  • Page 20: Mechanical Data

    4 to 20 mA Signal current Thermal snap-switches (IDX only) contact ratings Maximum voltage 24 V a.c./d.c. Maximum current (resistive load) Page 14 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 21: Lubrication Data

    A708-01-880 Issue E Lubrication data Note: An Edwards Material Safety Data Sheet for the oil referenced below is available on request. Table 5 - Lubrication Data Gearbox Oil capacity Minimum 5 l (1.32 US gal) Maximum 5.5 l (1.45 US gal)
  • Page 22: Temperature Control System

    Return outlet inch BSP male inch NPT male ¼ Shaft-seals purge gas inlet inch compression 50 Hz pumps † 60 Hz pumps Page 16 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 23: Coolant

    A708-01-880 Issue E 2.10 Coolant The pump is supplied filled with Edwards coolant which is monopropylene based, and is both an antifreeze and a corrosion inhibitor. Spare Edwards coolant is available: refer to Section 7.3. A Material Safety Data Sheet for the coolant is available on request.
  • Page 24: Materials Of Construction

    3. Fixing-holes: Ø18 mm (0.71 inch), 2 holes on each mounting foot 4. Fixing-holes: Ø17 mm (0.67 inch), 2 holes on each mounting bracket Page 18 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 25: Idx1000 Dimensions: Mm (Inch)

    A708-01-880 Issue E Figure 4 - IDX1000 Dimensions: mm (inch) * Maximum © Edwards Limited 2013. All rights reserved. Page 19 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 26: Idx1300 Dimensions: Mm (Inch)

    A708-01-880 Issue E Figure 5 - IDX1300 Dimensions: mm (inch) * Maximum Page 20 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 27 3. Fixing-holes: Ø18 mm (0.71 inch), 2 holes on each mounting foot 4. Fixing-holes: Ø17 mm (0.67 inch), 2 holes on each mounting bracket © Edwards Limited 2013. All rights reserved. Page 21 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 28: Cdx Dimensions: Mm (Inch)

    A708-01-880 Issue E Figure 6 - CDX Dimensions: mm (inch) * Maximum Page 22 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 29 This Figure shows a CDX with integral flame arrestors. The inlet/outlet dimensions on a CDX without integral flame arrestors are as shown in Figure © Edwards Limited 2013. All rights reserved. Page 23 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 30 A708-01-880 Issue E This page has been intentionally left blank. Page 24 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 31: Installation

    If the pump is not to be used immediately, replace the packing materials. Store the pump in suitable conditions as described in Section 6.1. © Edwards Limited 2013. All rights reserved. Page 25 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 32: Locate The Pump

    Section 3.3.2. Alternatively, the pump can be located without the mounting feet, as described in Section 3.3.3. Page 26 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 33: Locate The Pump On Its Mounting Feet

    Fit a second fixing bolt to each of the four pump mounting brackets. Tighten all eight of the fixing bolts to a torque of 100 N m (74 lbf ft). © Edwards Limited 2013. All rights reserved. Page 27 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 34: Check The Coolant Level

    MIN and MAX marks on the bezel (26) of either of the two oil- level sight-glasses. If necessary, pour more oil into the end cover: refer to Section 5.3.2. Page 28 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 35: Fill The Pump With Coolant

    1. Coolant drain plug 4. Coolant overflow pipe 2. Heat exchanger 5. Coolant filler tube 3. Coolant level sight-glass 6. Coolant filler cap © Edwards Limited 2013. All rights reserved. Page 29 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 36: Connect The Temperature Sensor (Cdx Pumps Only)

    5. Tighten the cable-gland, then refit the top cover (3). 6. Connect the other ends of the two control cable wires to the control circuit. Page 30 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 37: Connect The Cdx Temperature Sensor

    1. Terminal 1 B. General view 2. Terminal 2 C. Circuit schematic 3. Top cover 4. Cable leadthrough hole 5. Temperature sensor © Edwards Limited 2013. All rights reserved. Page 31 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 38: Connect The Oil Pressure Sensors (Cdx Pumps Only)

    The thermal snap-switches will reset (that is, close again) when the pump cools down to a preset temperature (see Section 2.8). Edwards recommends that the control equipment incorporates a manual reset device so that the pump does not automatically switch on after it cools down.
  • Page 39: Connect The Idx Thermal Snap-Switches

    3. Thermal snap-switch box 9. Shut-down thermal snap-switch 4. Four-core cable 10. Spade terminals 5. Cable-gland 11. Shut-down wires 6. Warning wires © Edwards Limited 2013. All rights reserved. Page 33 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 40: Connect The Oil Pressure Switches (Idx Pumps Only)

    Make the electrical connections to the pump motor as described in the following sections. Edwards recommends connecting the electrical supply to the pump motor through a suitable current monitor, and configuring the high current setting on the current monitor to switch off the pump motor at a suitable overload Page 34 ©...
  • Page 41: Connect The Electrical Supply To The Pump Motor

    Check the direction of pump rotation Note: The pump must be heated to at least +5 °C (41 °F) before starting or rotating the pump. © Edwards Limited 2013. All rights reserved. Page 35 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 42: Connect The Cooling Water Supply

    Refer to the ATEX system instruction manual for further details. Page 36 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 43: Connect The Pump Inlet And Outlet

    Where there is a risk that corrosive or dangerous condensates may form inside the pumping system, Edwards recommends fitting suitable heaters to the inlet and outlet pipelines. If necessary, contact Edwards or the supplier for advice.
  • Page 44: Connect The Pump Outlet

    Use suitable bolts to connect the pump outlet (Figure 1, or 3, item 16) to the exhaust system. Use a suitable PTFE gasket to seal the connection. Edwards recommends using the gasket type specified in Section 2.9.
  • Page 45: Leak Test The System

    0 (minimum) and 5 (maximum). These TCV settings correspond to the pump operating temperatures shown in Table © Edwards Limited 2013. All rights reserved. Page 39 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 46: Tcv Settings

    † End cover/gearbox (oil) temperature. Note: A nitrogen shaft-seals purge is required at the operating temperatures/conditions in the shaded cells above. Page 40 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 47: Minimum Pump Operating Temperatures (°F)

    † End cover/gearbox (oil) temperature. Note: A nitrogen shaft-seals purge is required at the operating temperatures/conditions in the shaded cells above. © Edwards Limited 2013. All rights reserved. Page 41 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 48 A708-01-880 Issue E This page has been intentionally left blank. Page 42 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 49: Operation

    Do not expose any part of the body to vacuum. If so, there will be danger of injury. The procedures in the following sections assume that there is a pump inlet isolation valve fitted to the pump. © Edwards Limited 2013. All rights reserved. Page 43 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 50: Atex System Control

    In the first 30 seconds of pumpdown, open the inlet isolation valve slowly if there is liquid in the inlet pipeline, in order to minimize the ingress of liquid (entrained in the process gas stream) into the pump. Page 44 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 51: Shut Down The Pump

    CAUTION If the pump is operating in an ambient temperature between -20 and -5 °C (-4 and 23 °F), Edwards recommends that the pump is never shut down, other than for maintenance. If doubts about this, contact Edwards for advice.
  • Page 52 A708-01-880 Issue E This page has been intentionally left blank. Page 46 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 53: Maintenance

    260 °C (500 °F) and above. These breakdown products are very dangerous. The pump may have overheated if it was misused, if it malfunctioned, or if it was in a fire. Edwards Safety Data Sheets for the fluorinated materials used in the pump are available on request: contact the supplier or Edwards.
  • Page 54: Check The Oil Levels

    Adjust the maintenance plan for IDX and non-ATEX pumps according to experience. When maintaining the pump, use Edwards maintenance and service kits. These contain all of the seals and other components necessary to complete maintenance operations successfully. The Item Numbers of these kits are given Section 7.3.
  • Page 55: Maintenance Plan

    6. Remove the funnel or nozzle from the oil filler port, then refit the oil filler plug and bonded seal (8). © Edwards Limited 2013. All rights reserved. Page 49 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 56: Check The Shaft-Seals Purge Gas Supply

    Section 5.5.2. 6. When refilling the pump: To refill a pump containing Edwards coolant with the same type Edwards coolant, continue at Step 4 of Section 3.4. To refill a pump containing Edwards coolant with a different coolant, drain the pump and continue at Section 5.5.2.
  • Page 57: Drain The Coolant And Refill The Pump With A Different Coolant

    Replace any of the pipelines and connections that are corroded or damaged. Check that all of the vent pipeline connections are secure. Tighten any loose connections. © Edwards Limited 2013. All rights reserved. Page 51 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 58: Change The Oil And Oil Filters, Drain The Vent Filters, And Clean The Oil Level Sight-Glasses

    2. Unscrew and remove the end cover oil filter (8) and gasket (7) from the filter port adaptor (5) on the end cover. 3. Dispose of the oil filter and gasket (8, 7) and the oil in the container: refer to Section 6.2. Page 52 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 59: Drain The End Cover Vent Filter

    6. Remove the funnel or nozzle from the oil filler port and refit the oil filler plug and bonded seal (Figure 1, 3, item 8) to the end cover. 7. Dispose of the used oil safely: refer to Section 6.2. © Edwards Limited 2013. All rights reserved. Page 53 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 60: Change The Oil Filters And Clean The Oil Level Sight-Glasses

    5. Filter port adaptor 13. O-ring 6. End cover oil drain plug 14. Bezel 7. Gasket 15. Screws (4 off) 8. Oil filter Page 54 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 61: Drain The Gearbox Oil And Clean The Gearbox Sight-Glasses

    5. Fit the new oil filter (8) and gasket (7) to the filter port adaptor (5) on the gearbox. Tighten by hand. © Edwards Limited 2013. All rights reserved. Page 55 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 62: Drain The Gearbox Vent Filter

    To remove deposits from a pump which has been operating correctly, or freeing a pump which has seized, use the procedure in this Section. Page 56 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 63 11, items 1 and 2) to the cleaning solution flush ports. 19. Dispose of the used cleaning solution and deposits removed. © Edwards Limited 2013. All rights reserved. Page 57 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 64: Clean The Cooling System

    Thoroughly flush the cooling system with clean water before starting work. Wear the appropriate Personal Protective Equipment (PPE) when cleaning the cooling system. Page 58 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 65: Drain The Coolant From The Cooling System

    3. Use a pipe cleaner which will pass through a 400 mm (15.75 inch) length of 5 mm (0.2 inch) diameter tube to clean and remove any scale from each tube in the tube stack (Figure 12, item 7) (Figure 13, item 8). © Edwards Limited 2013. All rights reserved. Page 59 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 66: Clean The Coolant Level Sight-Glass

    Ensure that the pump motor cannot fall when removing it. The pump motor is heavy and can cause injury to people if it falls. Page 60 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 67: Clean The Cooling System - Cdx/Idx1000

    21. Hex-head nut 6. Heat exchanger 14. Sight-glass 22. Gasket 7. Tube stack 15. Gasket 23. Filter body 8. O-ring 16. O-ring © Edwards Limited 2013. All rights reserved. Page 61 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 68: Clean The Cooling System - Idx1300

    22. Water fitting 7. Body extension 15. Right-hand end cap 23. Water fitting 8. Tube stack 16. Bolts (8 off) 24. Water fitting Page 62 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 69: Fit The New Pump Motor

    9. Undo and remove the four bolts (17) which secure one of the coupling covers (16) to the coupling housing (15), then remove the coupling cover. © Edwards Limited 2013. All rights reserved. Page 63 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 70: Check The Direction Of Pump Rotation

    (18), then slide the holding ring over the insert. 8. Tighten the set screws (7) to secure the holding ring (20) in place. Page 64 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 71: Clear A Hydraulic Lock (When Necessary)

    Ensure appropriate Personal Protective Equipment (PPE) is worn and observe all necessary safety precautions applicable to any hazardous substances which may be in the vent adaptor or exhaust elbow. © Edwards Limited 2013. All rights reserved. Page 65 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 72: Pump Motor And Drive Coupling

    19. Drive hub 6. Gasket 13. Key 20. Holding ring 7. Set screw 14. Pump shaft 21. Gap: 2.5 mm (0.098 inches) Page 66 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 73: Change The Bearings And Seals

    If referring to Table 16 but still cannot identify the cause of a fault, or cannot rectify a fault identified, contact the supplier or Edwards for advice. © Edwards Limited 2013. All rights reserved. Page 67...
  • Page 74: Clean The Vent Adaptor

    Figure 16 - Air bleed filter element cleaning/replace 1. Top cap 3. Filter element 2. Inlet 4. Filter body Page 68 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 75: Fault Finding

    Is the cooling water filter blocked? Clean the cooling water filter (refer Section 5.10.2). © Edwards Limited 2013. All rights reserved. Page 69 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 76 (refer to Section 5.11). Page 70 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 77: Storage And Disposal

    Fluoroelastomers which may have decomposed as the result of being subjected to high temperatures Components and oil which have been contaminated with dangerous process substances. © Edwards Limited 2013. All rights reserved. Page 71 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 78 A708-01-880 Issue E This page has been intentionally left blank. Page 72 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 79: Service, Spares And Accessories

    CDX and IDX pumps. Accessories A number of accessories are available for the CDX and IDX pumps, as listed below. Contact the supplier or Edwards for details of these accessories. Exhaust Silencers (mild steel or stainless steel)
  • Page 80: Spares And Maintenance Kits

    A708-01-822 Air Bleed Filter Replacement Kit A709-01-801 0.9 litres (0.24 US gal) as supplied, 2.0 litres (0.53 US gal) when diluted. Page 74 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 81: Index

    Connect the pump to your process system Lubrication data Connect the pump-outlet Connect the shaft-seals purge gas supply Maintenance Connect the temperature sensor Maintenance plan © Edwards Limited 2013. All rights reserved. Page 75 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 82 Spares and maintenance kits Start the pump Storage Storage and disposal Technical data Temperature control system Unpack and inspect the pump Page 76 © Edwards Limited 2013. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.