6.2.1 Shut down modes

Auto shut down introduces a nitrogen purge cycle which lasts for 15~90 minutes
before the pump is shut down. This is the recommended shut down mode.
Fast shut down immediately stops the pump without gas purge.
Ramped shut down is an optional mode for this system. In some harsh
applications, process residues can accumulate in the pump mechanism during shut
down and will make it difficult to restart the pump next time. To prevent this
problem a special ramped shut down can be performed. Contact your supplier for
more information.

6.2.2 Shut down through a MicroTIM

Use your control equipment to reset the pump start/stop signal to the interface
connector. The Running LEDs will then go off, and the pump running status output signal
will open.

6.2.3 Shut down through a PDT

1.
Press the Stop button on the PDT. Refer to
information.
2.
Select 'Auto' or 'Fast shut down' mode.

6.2.4 Shut down through the front panel control

1.
Press and hold the STOP button
the pump in 'Auto shut down' mode (recommended, refer to
page 63).
2.
Repeat in 10 seconds to stop the pump in 'Fast shut down' mode. The running LED
flashes while the pump slows down and will then turn off when the pump has shut
down.

6.2.5 Controlled stop

WARNING: HOT SURFACES
Risk of burn injury. For TX variants the exhaust heaters will remain powered on even
when the emergency stop is activated.
Note:
The controlled stop switch is not an electrical isolator.
To shut down the system in an emergency, press the EMS button
controls). Alternatively, the controlled stop controls can be operated in the customer's
own control system if the controlled stop circuit is connected to the system as described
in
Connect to the emergency stop circuit
When controlled stop is selected:
The dry pump and/or the booster pump is switched off.
M56635880_D
M56635880_D - Operation
(Figure: Front panel
on page 45.
Page 63
Table: Pump stop and control
controls) for 5 seconds to stop
Shut down modes
(Figure: Front panel
10/2020 - ©Edwards Limited
for more
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents