Relocate The System For Decommissioning - Edwards iXM Series Instruction Manual

Dry pump system
Table of Contents

Advertisement

These breakdown products are very dangerous. Fluorinated materials in the
system can include oils, greases and seals. The system has possibly overheated if it
was misused, if it malfunctioned or if it was in a fire. Edwards Safety Data Sheets
for fluorinated materials used in the pump are available on request.
The system requires no maintenance. Pump protection sensors installed in the system
do not require routine maintenance. The decommissioning operations that can be
carried out are described in
Drain the cooling water for decommissioning
out by our service centres (refer to
operations depends on the process.

9.2 Relocate the system for decommissioning

WARNING: USE PROTECTIVE EQUIPMENT
Risk of injury or death. The substances collected in the exhaust pipe, elbow and check
valve can be dangerous. Do not let these substances contact skin or eyes. Do not
inhale vapours from these substances. Install blanking caps to the inlet and outlet
flanges when moving the exhaust pipe, elbow or check valve around the workplace.
The majority of synthetic oils/grease can cause inflammation of the skin (dermatitis).
Safety precautions must be taken to prevent prolonged skin contact with these
substances. Use of correct protective gloves and clothing along with a respirator is
recommended if contact with the substance is possible. System process gases and
residue can be highly toxic. Take all necessary precautions when you handle the
components that have, or can have, come into contact with them, including O‑rings,
lubricants and all exhaust accessories.
WARNING: HEAVY OBJECT
Risk of physical injury. Use correct lifting equipment.
WARNING: TRANSPORTATION SAFETY
Risk of toppling. Do not exceed the topple angle of 10° when you move the system. If
the system topples it can cause personal injury or damage to the equipment. Move
the system on its castors to its operating position. The system should only be moved
for short distances over flat surfaces. If the floor surface is uneven or has obstacles
the system should be lifted with correct lifting equipment. If lifting the system is
impractical or there are other site difficulties, contact us for advice.
CAUTION: COOLING WATER TEMPERATURE
Risk of damage to equipment. Drain the cooling water from the system if transporting
or storing it in conditions where the cooling water can freeze. Failure to do so can
cause the cooling water to freeze in the system and damage the pump(s) and/or the
cooling water pipelines.
To relocate the system from the operating location for maintenance:
M56635880_D
M56635880_D - Decommissioning
Relocate the system for decommissioning
Service
Page 86
on page 87. Maintenance must be carried
on page 91). The frequency of maintenance
10/2020 - ©Edwards Limited
on page 86 and