Commission; Commission The System - Edwards iXM Series Instruction Manual

Dry pump system
Table of Contents

Advertisement

5. Commission

5.1 Commission the system

WARNING: USE PROTECTIVE EQUIPMENTS
Risk of injury. During some application cycles the system can possibly exceed OSHA
1910.95 Occupational Noise Exposure Limits, the EU noise directive 2003/10/EC or
other regional noise limits. The noise level depends upon the process, duty cycle,
installation or environment in which the system is being operated. A sound pressure
survey must be conducted after installation. If necessary, set up controls to make
sure that the relevant limits are not exceeded during operation and that precautions
are taken to prevent personnel from exposure to high noise levels during operation.
WARNING: HOT SURFACES
Risk of burn injury. The pump exhaust will heat up when the pump is in operation. Do
not touch the pump surface.
Refer to
1.
Switch on the external electrical supply and check that the POWER LEDs illuminate.
If the Light-Emitting Diodes (LEDs) do not illuminate, contact us.
2.
Switch on the cooling water and nitrogen supplies.
3.
Make sure that the exhaust extraction system is not blocked (for example, that
valves in the exhaust extraction system are open).
4.
Make sure that all openings to atmospheric pressure in the foreline vacuum system
are closed.
5.
Press the Local Control button and check that the green Local Control LED
illuminates and then remains continuously illuminated.
6.
Press Start button.
7.
If the dry pumping system starts and continues to operate, continue at Step 8. If a
warning or alarm condition is indicated:
8.
Monitor the pressure gauge in the inlet pipeline:
9.
After commissioning the system:
M56635880_D
M56635880_D - Commission
Figure: Front panel
controls:
Shut down the system: refer to
Contact us.
If the pressure is increasing, immediately shut down the system and contact
us.
If the pressure is decreasing continue at Step 9.
To continue to operate the system, refer to
Otherwise, shut down the system, refer to
Shut down
on page 62.
Start-up
Shut down
Page 49
on page 59.
on page 62.