Installing a NetIron XMR 16000 router
CAUTION
For the NEBS-compliant installation of NetIron XMR 4000, 8000, and 16000 routers with AC and
DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). The ground wire should
have an agency-approved crimped connector (provided with the device) attached to one end, with
the other end attached to building ground. The connector must be crimped with the proper tool,
allowing it to be connected to both ground screws on the enclosure. Before crimping the ground
wire into the provided ground lug, insure the bare copper wire has been cleaned and antioxidant
is applied to the bare wire.
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is
required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 115
1
AWG power supply wire
For 1200 W power supply, #8 AWG
For 1800 W power supply, #6 AWG
5. Connect the -48V cable to the negative terminal and the 0V cable to the positive terminal as
6. Replace the transparent plastic cover and screws.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for
regulations

Final steps

Follow these steps to complete the installation:
170
Crimping the power supply wire in the lug
marked on the power supply.
NOTE
DC return must be isolated from the device ground (DC-I) when connecting to the power supply.
"Attaching a management station"
"Activating the power source"
"Verifying proper operation"
1