Brocade Communications Systems MLX Series Hardware Installation Manual page 142

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

2
Verifying proper operation
TABLE 24
Router LED states and actions
LED label
Desired state
Active
On or blinking
Switch Fabric module
Pwr
On
Active
On
AC power supplies
ACOK
Green (steady)
DC OK
Green (steady)
ALM
Off
DC power supplies
DC IN
Green (steady)
126
Meaning
Abnormal
state
The port is
Off for an
transmitting and
extended
receiving user
period.
packets.
The module is
Off
receiving power.
The switch fabric
Off for an
module is active
extended
and ready to switch
period.
user packets.
The power supply is
Off
receiving power
from the AC power
source.
The power supply is
Off
providing AC power
to the router.
The power supply is
Amber
in normal operating
condition.
The power supply is
Off
receiving power
from the DC power
source.
Meaning or action
This LED will remain off until you have cabled the interface
module ports.
After cabling the ports, if this LED is still off, the port is not
transmitting or receiving user packets. For more information,
refer to
Table 30
on page 220.
The module is not receiving power. Check the following:
Make certain that the module is installed properly. For more
information, refer to the module installation section in this
chapter that applies to your router model.
If you are using AC power supplies, refer to the AC power
supply LED information in this table for more information.
The switch fabric module is not active and user packets are not
being switched from one interface module to another.
You must replace the switch fabric module. Refer to
switch fabric module"
on page 268.
The power supply is not receiving power from an AC power source
You can do the following:
Make sure that the power cord is connected securely to the
wall outlet and the power supply.
Make sure the wall outlet is rated for high line, 200-240 VAC
and 20A. If it is not, obtain a cable that is rated for the
outlet.
Make sure that the wall outlet has power.
The power supply is not supplying power to the device. If the AC
LED is green, there is a problem with the power supply and it
must be replaced.
The power supply is malfunctioning.
The power supply is not receiving power from a DC power source
You can do the following:
Make sure that the power supply cables are connected
securely to the power source and the power supply.
Make sure that the DC power source for MLX -4, -8, and -16
is 48 VDC @ 30 A. The DC power source for MLX-32 must be
48 VDC @60A. The operating voltage range is 40 to 60 VDC.
Make sure that the power source has power.
Brocade MLX Series and NetIron XMR Hardware Installation Guide
"Replacing a
53-1003821-01

Advertisement

Table of Contents
loading

Table of Contents