The router ships with slot blanks installed in all empty module slots. The slot blanks help ensure
proper airflow inside the router. You must remove the slot blank to install a module into a slot.
Although the slot blanks differ in size, the procedure for removing them is identical. You will need a
flat-blade screwdriver to perform this task.
Follow these steps to remove a slot blank.
1. Loosen the screws on either end of the slot blank by hand or with a flat-blade screwdriver.
2. Pull the slot blank out of the router, and store it in a safe place for future use.
CAUTION
If you are hot-swapping a module, allow a minimum of two seconds after a module (or power
supply or fan tray) has been removed before inserting a module in the same slot.
Follow these steps to install a module.
1. If you are installing a module in a slot which may have been configured for a different module
2. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on
3. Remove the module from the packaging.
4. Insert the module into the router slot, and slide the card along the card guide until the ejectors
5. Rotate the ejectors until they are flush with the module front panel. This action will fully seat
6. Tighten the two screws at either end of the module front panel by pushing them in and turning
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
type, remove the old configuration information by following these steps.
a. Use the show running-config command in config mode to determine the current
configuration of the slot.
Brocade(config)# show running-config
Current configuration:
!
ver V5.0.0T163
module 1 ni-mlx-20-port-1g-copper
!
This example shows that slot 1 has already been configured for a 20-port 1 Gbps copper
interface module.
With the module designation from show running-config command output, use the no
module slot-number module-type command to remove the configuration from slot 1.
Brocade(config)# no module 1 ni-mlx-20-port-1g-copper
This example removes the configuration from slot 1, leaving it ready for a new module.
the front of the chassis.
on either side of the module move close to the module front panel. Refer to
NOTE
When inserting the module into the router, be sure that the faceplate does not overlap the
faceplate of an adjacent module.
the module in the backplane.
them clockwise. Complete the tightening process using the flat-blade screwdriver.
Installing a Brocade MLX-8 router