6
Using alarms to collect and monitor device status
TABLE 42
Description
To display all alarms in the alarm log for all interface
modules and subsystems for the management
module.
To display all alarms in the alarm log for all SFM and
subsystems for the SFM.
Management and interface modules
When a management module or interface module is removed from the chassis, a major level alarm
is generated in the alarm history log. If the management module, interface module, or SFM is
powered off, a critical level alarm is generated in the alarm history log.
When a module is removed or powered off, alarms for all subsystems of the module are cleared
from the current alarm log. If a module is removed from the chassis, all alarms are cleared from the
current alarm log, and memory associated to its subsystems is freed. When a module is added to
the configuration, memory is reallocated.
256
Displaying alarm log information (Continued)
To display all alarms in the alarm log related to
temperature information for a management
module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and a specific fan
(where x, is the temperature device number).
To display all alarms in the alarm log related to
a specific interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and all alarms for it's subsystems.
To display all alarms in the alarm log related to
subsystem information for an interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and either all events on a specific subsystem,
or events for a particular subsystem
temperature
(where subsystem is
x
(where
, is a the device number).
To display all alarms in the alarm log related to
a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and all alarms for it's subsystems.
To display all alarms in the alarm log related to
SFM information for a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and either all events on a specific subsystem,
or events for a particular subsystem
temperature
(where subsystem is
fabric-element
)
x
(where
is 1-4 for a fabric element device
number).
Syntax
show alarm
[history] mp
x
[all |
]
show alarm
[history] lp all
show alarm
[history] lp
show alarm
[history] lp
x
|
]
optic
or
)
show alarm
[history] sfm all
show alarm
[history] sfm
show alarm
[history] sfm
x
[all |
]
or
Brocade MLX Series and NetIron XMR Hardware Installation Guide
n
temperature
n
all
n
subsystem [all
n
all
n
subsystem