Brocade Communications Systems MLX Series Hardware Installation Manual page 207

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

1. Use a Phillips screwdriver to remove the center screw that secures the safety cover. Remove
FIGURE 132
2. Use a #2 Phillips screwdriver to unscrew the power lugs. Refer to
FIGURE 133
1
1 Lug screws
3. Crimp the correct AWG wire into the power lugs:
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
the safety cover, as shown in
Removing the safety cover (2400W power supply and 3000W power supply displayed)
Removing the power lugs (2400W power supply and 3000W power supply displayed)
2
Power lug (2)
For 2400 W power supply, crimp #4 AWG
For 3000 W power supply, crimp #2 AWG.
Refer to
Figure
134.
Installing a NetIron XMR 32000 router
Figure
132.
2
3
Figure
133.
1
2
191