  • Page 1 March 31, 2009 NetIron CES 2000 Series Hardware Guide...
  • Page 2: Document History

    The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
  • Page 3: Table Of Contents

    Contents HAPTER ..................1-1 BOUT UIDE ............................1-1 NTRODUCTION .........................1-1 PDATES TO ANUAL ..............................1-2 UDIENCE ............................1-2 OMENCLATURE ..........................1-2 ELATED UBLICATIONS ....................1-2 OW TO ELP OR EPORT RRORS ............................1-2 CCESS ...........................1-2 MAIL CCESS ..........................1-2 ELEPHONE CCESS ..........................1-3 ARRANTY OVERAGE HAPTER .................. 2-1 RODUCT VERVIEW ............................2-1...
  • Page 4 Foundry Hardware Installation Guide for the NetIron CES 2000 Series ..........................2-9 EGIONS ........................2-9 ETWORK NTERFACES ..........................2-11 OWER UPPLIES AC P ........................2-12 OWER UPPLIES ..............................2-12 ........... 2-12 BOUT EDUNDANT OWER UPPLIES AND OWER UPPLY AILURE ......................2-13 OOLING YSTEM AND CES 2000 S ....................2-13...
  • Page 5 Contents CES 2000 S .................4-5 ONNECTING A ERIES WITCH .....................4-6 NSTALLING A IBER PTIC ODULE ......................4-6 ABLING A IBER PTIC ODULE ......................4-6 LEANING IBER PTIC ODULES HAPTER ETTING AMILIAR CES 2000 S ERIES WITCH ..............5-1 ANAGEMENT PPLICATIONS CLI .........................5-1 OGGING ON HROUGH THE .............................5-1...
  • Page 6 Foundry Hardware Installation Guide for the NetIron CES 2000 Series ....................7-3 ISPLAYING FLASH NFORMATION ....................7-5 ISPLAYING ERSION NFORMATION ..................7-5 ACKING P THE URRENT OFTWARE MAGES .......................7-5 IRTUAL NTERFACE ODULE ’ ...............7-6 PGRADING THE EVICE ONITOR AND MAGES CES 2000 S ....7-6...
  • Page 7 Contents ........................C-3 TORAGE NVIRONMENT ............................C-3 OOLING ......................C-3 AFETY GENCY PPROVALS ......................C-4 LECTROMAGNETIC PPROVALS ..........................C-4 PECIFICATIONS ..................... C-4 ONSOLE SSIGNMENTS ....................C-5 ANAGEMENT SSIGNMENTS March 2009 © 2008 Foundry Networks, Inc.
  • Page 8 Foundry Hardware Installation Guide for the NetIron CES 2000 Series viii © 2008 Foundry Networks, Inc. March 2009...
  • Page 9: About This Guide

    In order to meet these challenges, the NetIron Carrier Ethernet Switch (CES) 2000 Series was purpose-built to offer flexible, secure and advanced processing capabilities in a compact form factor. The NetIron CES 2000 Series is a compact 1 RU, multi-service edge/aggregation switch with a powerful set of capabilities chosen to combine performance with rich functionality at the edge of the network.
  • Page 10: Audience

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Audience This guide is designed for network installers, system administrators, and resellers who will install the NetIron hardware. This guide assumes a working knowledge of Layer 2 and Layer 3 switching and routing concepts.
  • Page 11: Warranty Coverage

    About This Guide Warranty Coverage Contact Brocade using any of the methods listed above for information about the standard and extended warranties. March 2009 © 2009 Brocade Communications Systems, Inc. 1 - 3...
  • Page 12 Foundry Hardware Installation Guide for the NetIron CES 2000 Series 1 - 4 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 13: Chapter 2 Product Overview

    • NetIron CES 2048F — accommodates 48-port 100/1000 Hybrid Fiber (HF) model • NetIron CES 2048FX — accommodates 48-port 100/1000 Hybrid Fiber (HF) model with 2x10G XFP uplink ports March 2009 © 2009 Brocade Communications Systems, Inc. 2 - 1...
  • Page 14: Product Overview

    Figure 2.2 Product Overview The NetIron CES 2000 Series is a compact 1 RU, multi-service edge/aggregation switch with a powerful set of capabilities that combine performance with rich functionality at the network edge. The NetIron CES 2000 Series switch offers network planners a broad set of high performance IPv4, Classic Layer 2, Provider Bridge (PB) and Provider Backbone Bridge (PBB) functionalities in the same device.
  • Page 15: Upgrade Applications

    To convert your NetIron CES 2000 Series, you need an upgrade kit. The kit includes a Dual Inline Package (DIP) key, Multi-Service IronWare software, upgrade instructions, and other items. Alternatively, you can order an NetIron CES 2000 Series device with the ME_PROM or the L3_PROM software already installed.
  • Page 16: Netiron Ces 2048C

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Figure 2.5 NetIron CES 2024F Device Combo 100/1000 Fiber 24 Port Fiber 24 Fiber Ports uplink/downlink Ports 21 23 14 16 18 20 22 24 NetIron CES 2048C NetIron CES 2048C has 48-ports of 10/100/1000 RJ45 with 4 combination 100/1000 Hybrid Fiber (HF) ports, and a required AC power supply.
  • Page 17: Netiron Ces 2048Cx

    38 40 42 44 46 48 20 22 24 28 30 32 34 36 Control Features Each NetIron CES 2000 Series front panel has a combination of the following control features: • Serial management interface (the port labeled Console) •...
  • Page 18: Netiron Ces 2000 Series Network Interfaces

    This section describes the port types in the NetIron CES 2000 Series. 10/100/1000 Mbps Ports The 100/1000 ports on the NetIron CES 2000 Series use auto-sensing and auto-negotiating to determine the speed (10 Mbps, 100 Mbps, or 1000 Mbps) and duplex mode (full-duplex or half-duplex) of the port at the other end of the link and adjust port speed accordingly.
  • Page 19: Supported Optics

    See “Installing or Replacing a 10-Gigabit Ethernet Module” on page 6-5. The 10-Gigabit Ethernet ports use 10-Gigabit Small Form Factor Pluggable (XFP) MSA-compliant transceivers. Table 2.4: LEDs for the NetIron CES 2000 Series Ports Position...
  • Page 20 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Table 2.5: SFP-Compliant Transceivers for the 100/1000 Ethernet Interface Module Part Number Description E1MG-LHB 1000Base-LHB SFP optic, single-mode fiber, LC connector, 150km Maximum Reach E1MG-BXD 1000Base-BXD SFP optic single-mode fiber, 1490nm, LC connector.
  • Page 21: Port Regions

    : Copper Vendor: , Version: Unknown Part# : Unknown, Serial#: Unknown Port 1/8: Type : Copper Vendor: , Version: Unknown Part# : Unknown, Serial#: Unknown Port 1/9: Type : Copper March 2009 © 2009 Brocade Communications Systems, Inc. 2 - 9...
  • Page 22 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Vendor: , Version: Unknown Part# : Unknown, Serial#: Unknown Port 1/10: Type : Copper Vendor: , Version: Unknown Part# : Unknown, Serial#: Unknown Port 1/11: Type : Copper Vendor: , Version:...
  • Page 23: Power Supplies

    Syntax: show media Power Supplies Each NetIron CES 2000 Series switch comes with one alternating-current (AC) power supply. All models have two power supply slots, enabling you to install a second power supply for redundancy. CAUTION: Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
  • Page 24: Ac Power Supplies

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series AC Power Supplies Figure 2.10 shows a rear view of a NetIron CES 2000 device containing one AC power supply. Figure 2.10 AC Power Supply Power Supply Fans DC Power Supplies Figure 2.11 shows the NetIron CES Series DC power supply.
  • Page 25: Cooling System And Fans

    6 Cooling Fans NetIron CES 2000 Series Fans The NetIron CES 2000 Series device cooling fans use pull configuration to move the air from the front to the back of the device. The fans in the NetIron CES Series switches include six four-speed fans that operate at low speed, medium speed, medium-high speed, and high speed based on the ambient temperature and configured or default temperature thresholds.
  • Page 26 Foundry Hardware Installation Guide for the NetIron CES 2000 Series 2 - 14 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 27: Chapter 3 Installation

    Installation WARNING: The procedures in this manual are for qualified service personnel. This chapter describes how to physically install a NetIron CES 2000 Series device. Information about configuring IP addresses and connecting network devices is in the chapter “Connecting a NetIron CES 2000 Series Switch to a Network Device”...
  • Page 28: Summary Of Installation Tasks

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Summary of Installation Tasks Follow the steps listed below to install your NetIron CES 2000 Series device. Details for each of the steps highlighted below are provided in this chapter and in the following chapter.
  • Page 29: Installation Precautions

    The power supply produces extensive power. Installing the power supply in a device other than the NetIron CES and CER 2000 Series devices will cause extensive damage to your equipment. March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 3...
  • Page 30: Preparing The Installation Site

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series WARNING: Disconnect the power cord from all power sources to completely remove power from the device. WARNING: Make sure to choose the appropriate circuit device depending on the number of AC power supplies installed in the chassis.
  • Page 31: Installing A Redundant Power

    Installation Installing a Redundant Power Supply The NetIron CES 2000 Series device ships with one alternating-current (AC) power supply or direct-current (DC) power supply. All models have two power supply slots, enabling you to install a second power supply for redundancy.
  • Page 32 Connect the plug end of the power cord into an outlet. CAUTION: For the NEBS compliant installation of a NetIron CES 2000 Series devices with AC and DC system use a ground wire of at least 8 American Wire Gauge (AWG). The ground wire should have an agency-approved crimped connector (provided with the chassis) attached to one end, with the other end attached to building ground.
  • Page 33: Installing An Dc Power

    All references to right-side and left-side are referenced from looking at the device from the front. Secure the two screws near the edges of the supply to lock the supply in place. March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 7...
  • Page 34: Installing The Device

    CAUTION: For the NEBS compliant installation of a NetIron CES 2000 Series devices with AC and DC system use a ground wire of at least 8 American Wire Gauge (AWG). The ground wire should have an agency-approved crimped connector (provided with the chassis) attached to one end, with the other end attached to building ground.
  • Page 35: Forward Rack Mount

    Forward Rack Mount Position The NetIron CES 2000 device ships with the rack ears attached to the front of the device as shown below: Figure 3.4 Front Rack Mount Position March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 9...
  • Page 36 Foundry Hardware Installation Guide for the NetIron CES 2000 Series 5 Inch Offset Rack Mount Position Figure 3.5 5 Inch Offset Rack Mount Position 3 - 10 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 37 Installation Mid Rack Mount Position Figure 3.6 Mid Rack Mount Position March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 11...
  • Page 38: Reverse Rack Mount

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Reverse Rack Mount Position Figure 3.7 Reverse Rack Mount Position CAUTION: When attaching the chassis to the rack, star washers shall be used to provide better grounding of the chassis to the rack. Additionally if any single hole grounding lugs are used star washers shall be used as a means to prevent rotation of the lug.
  • Page 39: Powering On The System

    Attach the AC power cable to the AC connector on the rear panel. Insert the power cable plug into a 115V/120V outlet. NOTE: To turn the system off, simply unplug the power cord(s). March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 13...
  • Page 40: Verifying Proper Operation

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series NOTE: The socket should be installed near the equipment and should be easily accessible. NOTE: If the outlet is not rated 115/120V, stop and get the appropriate cable for the outlet.
  • Page 41 No DC power. panel No DC power. Green blinking Supply has DC power, but output is not enabled. Green steady Supply has DC power, is enabled, and has good output. March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 15...
  • Page 42: Attaching Apc Or Terminal

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series LEDs for Power and Fans for the NetIron CES 2048 Models Table 3.3: LEDs for Power for the CES 2048 Models Position State Meaning Fan (labeled fn) Right side of...
  • Page 43 Foundry system. The EIA/TIA 232 serial communication port serves as a connection point for management by a PC or SNMP workstation. March 2009 © 2009 Brocade Communications Systems, Inc. 3 - 17...
  • Page 44 Foundry Hardware Installation Guide for the NetIron CES 2000 Series 3 - 18 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 45: Connecting A Net Iron

    WARNING: The procedures in this manual are for qualified service personnel. Assigning Permanent Passwords By default, the NetIron CES 2000 Series switch’s CLI is not protected by passwords. To secure CLI access, Brocade strongly recommends assigning passwords. (For additional information on security, see the Foundry Security Guide.)
  • Page 46: Configuring Ip Addresses

    Passwords can be up to 48 characters long. Configuring IP Addresses The NetIron CES 2000 Series switch implement separate data and control planes. This architecture affects how you assign IP addresses. Table 4.1 outlines the interfaces to which you can assign IP addresses.
  • Page 47: Support Of Sub-Net Masks

    How to assign an IP address to an interface or virtual interface over which user packets are routed Support of Sub-Net Masks The NetIron CES 2000 Series switch supports both classical IP network masks (Class A, B, and C sub-net masks, and so on) and Classless Interdomain Routing (CIDR) network prefix masks.
  • Page 48 Foundry Hardware Installation Guide for the NetIron CES 2000 Series NetIron# configure terminal Privileged EXEC Level NetIron(config)# Global CONFIG Level Configure the IP address and mask for the management interface by entering the following commands: NetIron(config)# interface management 1 NetIron(config-if-mgmt-1)# ip address 10.0.1.1 255.255.255.0 Syntax: enable [<password>]...
  • Page 49: Interface

    Enabling and Disabling the Interfaces By default, all NetIron CES 2000 Series interfaces are disabled. To enable an interface, you must enter the enable command at the appropriate interface configuration level of the CLI. For example, to enable the management...
  • Page 50 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Installing a Fiber-Optic Module To connect a NetIron CES 2000 Series switch to another network device using a fiber port, do the following: • Install a fiber optic module (SFP transceiver or XFP as required by your interface module) WARNING: All fiber-optic interfaces use Class 1 Lasers.
  • Page 51: Getting Familiar With

    VLANs, for routing protocols, and other configuration areas. NOTE: By default, any user who can open a direct or Telnet connection to a NetIron CES 2000 Series Switch can access all these CLI levels. To secure access, you can configure Enable passwords or local user accounts, or you can configure the device to use a RADIUS or TACACS/TACACS+ server for authentication.
  • Page 52: Command Completion

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series enter part of a command, then enter “?” or press Tab, the CLI lists the options you can enter at this point in the command string. If you enter an invalid command followed by ?, a message appears indicating the command was unrecognized.
  • Page 53: More-- Prompt.

    Getting Familiar With the NetIron CES 2000 Series Switch Management Applications Table 5.1: CLI Line Editing Commands (Continued) Ctrl-Key Combination Description Ctrl-C Escapes and terminates command prompts and ongoing tasks (such as lengthy displays), and displays a fresh command prompt.
  • Page 54: E Xpressions

    The following command filters the output of the show who command so it displays only lines that do not contain the word “closed”. This command can be used to display open connections to a NetIron CES 2000 Series Switch. NetIron # show who | exclude closed...
  • Page 55: C Onfiguration F Iles

    Getting Familiar With the NetIron CES 2000 Series Switch Management Applications Searching and Filtering Output at the --More-- Prompt The --More-- prompt displays when output extends beyond a single page. From this prompt, you can press the Space bar to display the next page, the Return or Enter key to display the next line, or Ctrl-C to cancel the display.
  • Page 56: Filtering

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series The filtered results are displayed: filtering... telnet Telnet by name or IP address To display lines that do not contain a specified search string (similar to the exclude option for show commands) press the minus sign key ( - ) at the --More-- prompt and then enter the search string.
  • Page 57 Getting Familiar With the NetIron CES 2000 Series Switch Management Applications Table 5.2: Special Characters for Regular Expressions (Continued) Character Operation The question mark matches on zero occurrences or one occurrence of a pattern. For example, the following regular expression matches output that contains "dg" or "deg":...
  • Page 58 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Table 5.2: Special Characters for Regular Expressions (Continued) Character Operation A vertical bar separates two alternative values or sets of values. The output can match one or the other value.
  • Page 59: Replacing A Power Supply

    2 x10-Gigabit Ethernet module (only on the NetIron CES 2024C and NetIron CES 2024F models). Replacing a Power Supply You can replace a power supply while the NetIron CES 2000 Series switch is powered on and running. The power supplies are located in slots at the rear of the NetIron CES 2000 Series switch.
  • Page 60: Installation Precautions And Power

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Installation Precautions and Warnings Follow these precautions when installing a power supply in the NetIron CES 2000 Series switch. WARNING: Before beginning the installation, see the precautions in “Power Precautions” on page 3-3.
  • Page 61: Removing An Ac Power

    Table 6.1 outlines the LEDs, the desired state of each LED, possible abnormal states of each LED, and what to do if an LED indicates an abnormal state. March 2009 © 2009 Brocade Communications Systems, Inc. 6 - 3...
  • Page 62 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Table 6.1: LEDs for Power State Meaning Fan (labeled Fn) The fan tray is powered on and is operating normal. The fan tray is not powered on, or has been removed.
  • Page 63: Removing A

    The 2-port 10-Gigabit Ethernet modules may optionally be installed or replaced in the field on the NetIron CES 2024C and NetIron CES 2024F units. You can order the NetIron CES 2000 Series with a 2 x10-Gigabit module installed at the factory, or you can later upgrade your device.
  • Page 64: Replacing A Fiber Optic Module

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Replacing a Fiber Optic Module You can remove an SFP or XFP from a port and replace it with a new one while the NetIron CES and CER 2000 Series devices device is powered on and running.
  • Page 65: Odule

    When not using an SFP or XFP connector, make sure to keep the protective covering on. Upgrading the Software For software upgrade instructions, see the release notes or the Foundry NetIron Configuration Guide. March 2009 © 2009 Brocade Communications Systems, Inc. 6 - 7...
  • Page 66 Foundry Hardware Installation Guide for the NetIron CES 2000 Series NOTE: The device must have an IP address. If the device does not already have an IP address, configure one by entering the ip address <ip-addr> <ip-mask> command at the global CONFIG level of the CLI.
  • Page 67: Equired

    Chapter 7 Upgrading Software Images and Configuration Files This chapter describes the software images required to operate a NetIron CES 2000 Series Switch and how to load them onto the switch. The images required are described in Table 7.1. Table 7.1:...
  • Page 68: Ervice Iron Ware Software

    • Displaying the Flash Memory and Version Information – This sub-section describes the commands that allow you to determine the contents of the NetIron CES 2000 Series switch’s flash memory and how to read the output of those commands. •...
  • Page 69 Displaying Flash Memory and Version Information Prior to upgrading the images on a NetIron CES 2000 Series switch, it is advisable to check the versions already installed. This allow you to determine which versions need to be upgraded. It is also useful to check the versions installed immediately after an upgrade has been done to make sure that you have installed the versions required in your installation.
  • Page 70 Indicates the Multi-Service IronWare image installed in the primary or (Primary or Secondary) secondary location in the NetIron CES 2000 Series Switches code flash. The image must be ce <xxxxx>. The actual image name depends on the version of software you have running on your switch.
  • Page 71: Version Information

    Syntax: show version The highlighted lines in the output indicate the versions currently running boot, monitor and Multi-Service IronWare images for the NetIron CES 2000 Series Switches. The fields are described in Table 7.3 except for the following: The "HW:" line indicates the hardware ("NetIron CES") and the type of software package enabled on the unit. The type of software package enabled on the system can be one of the following: •...
  • Page 72 Foundry Hardware Installation Guide for the NetIron CES 2000 Series The <slot-number> parameter specifies the chassis slot number of the virtual interface module to which you want to open an rconsole session. For the NetIron CES 2000 Series switch, this should always be 1. Syntax: enable Syntax: exit Syntax: Ctrl-X"...
  • Page 73 NOTE: You can name the configuration file when you copy it to a TFTP server. However, when you copy a configuration file from the server to a NetIron CES 2000 Series switch, the file is always copied as “startup-config” or “running-config”, depending on which type of file you saved to the server.
  • Page 74 • copy running-config tftp <tftp-ip-addr> <filename> – Use this command to upload a copy of the running configuration from the NetIron CES 2000 Series switch to a TFTP server. • copy tftp startup-config <tftp-ip-addr> <filename> – Use this command to download a copy of the startup- config from a TFTP server to a switch.
  • Page 75 10.10.10.69/24 This time, the CLI accepts the command, and no error message is displayed: NetIron(config)# interface ethernet 3/1 NetIron(config-if-e1000-1/1)# no ip add 10.10.10.1/24 NetIron(config-if-e1000-1/1)# ip add 10.10.10.69/24 March 2009 © 2009 Brocade Communications Systems, Inc. 7 - 9...
  • Page 76 You can use an SNMP management application such as Brocade's IronView Network Manager or any third-party SNMP management application to save and load a NetIron CES 2000 Series switch's configuration. To save and load configuration information using such an SNMP management application, use the following procedure.
  • Page 77 <dd:hh:mm> is the number of days, hours, and minutes. primary | secondary specifies whether the reload is to occur from the primary code flash image or the secondary code flash image. March 2009 © 2009 Brocade Communications Systems, Inc. 7 - 11...
  • Page 78: Error

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Diagnostic Error Codes and Remedies for TFTP Transfers If an error occurs with a TFTP transfer to or from a NetIron CES 2000 Series Switch, one of the following error codes are displayed.
  • Page 79: Upgrade Kit Contents

    Los procedimientos de este manual se han hecho para personal de servicio cualificado. Table 7.5: NetIron CES 2000 Upgrade Part Numbers Upgrade Prom Description NI-CES2024-MEU Metro Edge Premium upgrade for NetIron CES 2000 Series 24-port models NI-CES2024-L3U L3 Premium upgrade for NetIron CES 2000 Series 24-port models NI-CES2048-MEU...
  • Page 80: Hardware Installation

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Hardware Installation You need a Phillips-head screwdriver and an ESD wrist strap to perform this procedure. You also need a static- free work area. To perform the upgrade: Remove the power cable(s) from the device.
  • Page 81 CAUTION: Do not push too hard. If the DIP key does not readily go into the DIP socket, stop pushing and verify that the lead pins are straightened and properly aligned over the holes, straighten any lead pins that need straightening, then try again. March 2009 © 2009 Brocade Communications Systems, Inc. 7 - 15...
  • Page 82 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Figure 7.3 DIP Key Insertion for NetIron CES 2024 Pin 1 EEPROM Socket Figure 7.4 DIP Key Insertion for NetIron CES 2048. Pin 1 EEPROM Socket 7 - 16 © 2009 Brocade Communications Systems, Inc.
  • Page 83 Re-insert the power cable(s) to power on the device. There is no change required in the software image after upgrading the premium package, in order to utilize the capabilities enabled by the premium software package. March 2009 © 2009 Brocade Communications Systems, Inc. 7 - 17...
  • Page 84 Foundry Hardware Installation Guide for the NetIron CES 2000 Series 7 - 18 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 85: Cautions And Warnings

    “Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel. March 2009 © 2009 Brocade Communications Systems, Inc. A - 1...
  • Page 86 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Un mensaje de precaución le advierte sobre un posible peligro que pueda dañar el equipo. Las siguientes son precauciones utilizadas en este manual. CAUTION: Remove the power cord from a power supply before you install it in or remove it from the device.
  • Page 87 PRECAUCIÓN: Use un circuito derivado separado para cada cordón de alimentación de CA, con lo que se proporcionará redundancia en caso de que uno de los circuitos falle. March 2009 © 2009 Brocade Communications Systems, Inc. A - 3...
  • Page 88 Foundry Hardware Installation Guide for the NetIron CES 2000 Series CAUTION: Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of all devices installed on the same circuit as the device.
  • Page 89 VORSICHT: Lassen Sie keine Werkzeuge im Chassis zurück. MISE EN GARDE: Ne laissez jamais d'outils à l'intérieur du châssis. PRECAUCIÓN: No deje nunca herramientas en el interior del chasis. March 2009 © 2009 Brocade Communications Systems, Inc. A - 5...
  • Page 90 Foundry Hardware Installation Guide for the NetIron CES 2000 Series CAUTION For DC power supplies (part number RPS9-DC), use a grounding wire of at least 12 American Wire Gauge (AWG). VORSICHT Benutzen Sie für DC-Netzteile (Teilenummer RPS9-DC) einen Erdungsdraht mit wenigstens 12 AWG (American Wire Gauge).
  • Page 91: Warnings

    "Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führen können. Sie finden die folgenden Warnhinweise in diesem Handbuch: Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci-dessous, vous trouverez les avertissements utilisés dans ce manuel. March 2009 © 2009 Brocade Communications Systems, Inc. A - 7...
  • Page 92 Foundry Hardware Installation Guide for the NetIron CES 2000 Series Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci-dessous, vous trouverez les avertissements utilisés dans ce manuel. WARNING: The procedures in this manual are for qualified service personnel.
  • Page 93 Esta marca será su garantía de que el cordón de corriente puede ser utilizado con seguridad con el instrumento. March 2009 © 2009 Brocade Communications Systems, Inc. A - 9...
  • Page 94 Foundry Hardware Installation Guide for the NetIron CES 2000 Series WARNING: Power supplies are hot swappable. However, Brocaderecommends that you disconnect the power supply from AC power before installing or removing the supply. The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.
  • Page 95 à grande vitesse. ADVERTENCIA: Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. March 2009 © 2009 Brocade Communications Systems, Inc. A - 11...
  • Page 96 Foundry Hardware Installation Guide for the NetIron CES 2000 Series A - 12 © 2009 Brocade Communications Systems, Inc. March 2009...
  • Page 97: Regulatory Statements

    Machine noise information regulation - 3. GPSGV, the highest sound pressure level value is 60.0 dB(A) in accordance with EN ISO 7779. Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 60.0 dB(A) gemäss EN ISO 7779. March 2009 © 2009 Brocade Communications Systems, Inc. B - 1...
  • Page 98: Japan

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Japan The following statement applies to the NetIron CES 2000 Series Switches. English Translation of above statement This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI).
  • Page 99: Appendix C Hardware Specifications

    “Power Specifications” • “Physical Dimensions” • “Operating Environment” • “Storage Environment” • “Safety Agency Approvals” Power Specifications This section contains the power specifications for the NetIron CES 2000 Series chassis. March 2009 © 2009 Brocade Communications Systems, Inc. C - 1...
  • Page 100: Physical Dimensions

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Table 1 provides the maximum power calculations for the NetIron CES 2000 Series chassis. Table C.1: Maximum Power Calculations at 100-240 VAC NetIron Chassis Amps Watts BTUs Per Hour NetIron CES 2024C 1.45...
  • Page 101: Storage Environment

    EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and User’s Guide • EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications Systems • EN 60950-1:2001\IEC 60950-1 Safety of Information Technology Equipment March 2009 © 2009 Brocade Communications Systems, Inc. C - 3...
  • Page 102: Electromagnetic Approvals

    Foundry Hardware Installation Guide for the NetIron CES 2000 Series Electromagnetic Approvals • FCC Part 15, Subpart B (Class A) • EN 55022 (CE mark) (Class A) • EN55024 (CE mark) (Immunity) for Information Technology Equipment • ICES-003 (Canada) (Class A) •...
  • Page 103: Management Port Pin Assignments

    Table C.5: Management Port Pin Assignments Pin Number MDI-X Ports Not used (10BaseT) CMT (100BaseTX) Not used (10BaseT) CMT (100BaseTX) Not used (10BaseT) CMT (100BaseTX) Not used (10BaseT) CMT (100BaseTX) March 2009 © 2009 Brocade Communications Systems, Inc. C - 5...