CAUTION
For the NEBS-compliant installation of Brocade MLXe-32, routers with AC and DC systems, use a
ground wire of at least 2 American Wire Gauge (AWG). The ground wire should have an
agency-approved crimped connector (provided with the device) attached to one end, with the
other end attached to building ground. The connector must be crimped with the proper tool,
allowing it to be connected to both ground screws on the enclosure. Before crimping the ground
wire into the provided ground lug, ensure the bare copper wire has been cleaned and antioxidant
is applied to the bare wire.
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is
required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 51
1
4. Connect the -48V cable to the negative terminal and the 0V cable to the positive terminal.
5. Replace the transparent cover over the lugs.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for
regulations.

Final steps

Complete these steps in the order listed:
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Crimping the power supply wire in the lug
1
AWG power supply wire:
#8 AWG power supply wire for 1200W power supplies
#6 AWG power supply wire for 1800W power supplies
NOTE
DC return must be isolated from the router ground (DC-I) when connecting to DC power
supplies.
"Attaching a management station"
"Activating the power source"
"Verifying proper operation"
Installing a Brocade MLXe-4 router