Brocade Communications Systems MLX Series Hardware Installation Manual page 73

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

NOTE
Because there are multiple power supply vendors, the LED layout on your DC power supply may differ
from what is shown in
Follow these steps to connect a DC power source:
1. Use a #1 Phillips screwdriver to remove the two screws that hold the transparent cover over
FIGURE 41
1
Screws holding transparent cover
2. Use a #2 Phillips screwdriver to remove the power lugs.
3. Crimp #8 AWG power supply wire into the power lugs and reconnect the lugs to the power
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for
regulations.
CAUTION
For the NEBS-compliant installation of Brocade MLX 4-, 8-, and 16-slot routers with AC and DC
systems, use a ground wire of at least 6 American Wire Gauge (AWG). The ground wire should
have an agency-approved crimped connector (provided with the router) attached to one end, with
the other end attached to building ground. The connector must be crimped with the proper tool,
allowing it to be connected to both ground screws on the enclosure. Before crimping the ground
wire into the provided ground lug, ensure the bare copper wire has been cleaned and antioxidant
is applied to the bare wire.
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Figure
41. However, the LED functions are identical.
the power supply lugs, as shown in
The Brocade MLX-4 DC power supply
supply unit. Refer to
Figure
Installing a Brocade MLX-4 router
Figure
41.
2 Power lug screws
42.
2
57