Brocade Communications Systems MLX Series Hardware Installation Manual page 83

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

NOTE
Because there are multiple power supply vendors, the LED layout on your DC power supply may differ
from what is shown in
Follow these steps to connect a DC power source.
1. Use a #1 Phillips screwdriver to remove the two screws that hold the transparent cover over
FIGURE 49
1
Screws holding transparent cover
2. Use a #2 Phillips screwdriver to remove the power lugs.
3. Crimp #8 AWG power supply wire into the power lugs and reconnect the lugs to the power
CAUTION
For the NEBS-compliant installation of Brocade MLXe-4, Brocade MLXe--8, and Brocade MLXe-16
routers with AC and DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). The
ground wire should have an agency-approved crimped connector (provided with the device)
attached to one end, with the other end attached to building ground. The connector must be
crimped with the proper tool, allowing it to be connected to both ground screws on the enclosure.
Before crimping the ground wire into the provided ground lug, ensure the bare copper wire has
been cleaned and antioxidant is applied to the bare wire.
CAUTION
For the NEBS-compliant installation of Brocade MLXe-32, routers with AC and DC systems, use a
ground wire of at least 2 American Wire Gauge (AWG). The ground wire should have an
agency-approved crimped connector (provided with the device) attached to one end, with the
other end attached to building ground. The connector must be crimped with the proper tool,
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Figure
49. However, the LED functions are identical.
the power supply lugs, as shown in
The Brocade MLX-8 DC power supply
supply unit. Refer to
Figure
Installing a Brocade MLX-8 router
Figure
49.
2 Power lug screws
50.
2
67

Advertisement

Table of Contents
loading

Table of Contents