Installing Netiron Xmr 8000 Modules - Brocade Communications Systems MLX Series Hardware Installation Manual

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

1
4. Slide the router down so that the screw heads are in the narrow portion of the keyhole slots.
5. Tighten the screws to secure the router.
NOTE
For better grounding of the router to the rack, attach the router using star washers. You can also use
star washers with single hole grounding lugs to prevent rotation of the lug.
6. Add additional screws as required.
7.

Installing NetIron XMR 8000 modules

The NetIron XMR 8000 router ships with the required switch fabric modules installed.
The sequence for installing multiple modules is important to ensure proper fit. For the NetIron XMR
8000 router, start from the lowest row and move up, from right-to-left. The procedure in this section
applies to all modules.
For instructions about installing 2x100GbE interface modules, refer to
interface modules in NetIron XMR routers"
DANGER
The intra-building ports of the equipment or subassembly is suitable for connection to
intra-building or unexposed wiring or cabling only. The intra-building ports of the equipment or
subassembly MUST NOT be metallically connected to interfaces that connect to the outside plant
(OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Standard 19-inch rack
Repeat step 2 through step 6 to mount each router in the rack.
Installing a NetIron XMR 8000 router
2
Mounting screws
on page 137.
1
2
"Installing 2x100GbE
3
153

Advertisement

Table of Contents
loading

Table of Contents