Brocade Communications Systems MLX Series Hardware Installation Manual page 161

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the router
with an uncovered slot, it may overheat. Tighten the screws that secure the slot blanks so that
they remain in place when removing adjacent panels or modules.
Although slot blanks differ in size, the procedure for removing them is the same. The procedure in
this section applies to all slot blanks. You will need a flat-blade screwdriver to perform this task.
Follow these steps to remove a slot blank:
1. Loosen the screws on each end of the slot blank by hand or with a flat-blade screwdriver.
2. Pull the slot blank out of the router, and store it in a safe place for future use.
Before installing modules in the NetIron XMR 4000 router, have these items available:
DANGER
For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.
Although slot blanks differ in size, the procedure for removing them is the same. The procedure in
this section applies to all slot blanks. You will need a flat-blade screwdriver to perform this task.
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the router
with an uncovered slot, it may overheat. Tighten the screws that secure the slot blanks so that
they remain in place when removing adjacent panels or modules.
Follow these steps to remove a slot blank.
1. Loosen the screws on each end of the slot blank by hand or with a flat-blade screwdriver.
2. Pull the slot blank out of the router, and store it in a safe place for future use.
CAUTION
If you are hot-swapping a module, allow a minimum of two seconds after a module (or power
supply or fan tray) has been removed before inserting a module in the same slot.
Follow these steps to install a module in the NetIron XMR 4000 router.
1. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on
2. Remove the module from the packaging.
Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
A large flat blade screwdriver.
An ESD wrist strap with a plug for connection to the ESD connector on the router.
the router chassis.
Installing a NetIron XMR 4000 router