Brocade Communications Systems MLX Series Hardware Installation Manual page 256

Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

6
Managing the cooling system
TABLE 38
This field...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_<
module>)
Fan Speed Low or Med or Med-Hi or
Hi
State = 0 (FAN_STATE_LOW)
max_ts_shut_off_count
shut_off_count = 0 0 0 0 0 0 0 0
When syslog messages display a change in fan speed, you can identify which sensors triggered the
change by checking show chassis and show fan-threshold command output and looking for
sensors with temperatures near threshold
show chassis, show fan-threshold, and fan-threshold commands.
NOTE
A "thermal block" refers to the group of high and low thresholds for all fan speed levels.
TABLE 39
show chassis command output
(sensors)
MP, SFM, and hSFM Modules
Active Management 1st reading
Active Management 2nd reading THERMAL_SENSOR_TEST_RULE_MP_CPU
Standby Management 1st
reading
Standby Management 2nd
reading
SFM FE1 reading
SFM FE2 reading
SFM FE3 reading
hSFM FE1 reading
hSFM FE2 reading
hSFM FE3 reading
LP Modules (1 or 2 Traffic Managers)
LP Sensor 1 reading (TM 0)
240
Temperature threshold information for modules and fan speeds
Displays...
The temperature threshold information for the various modules. The
<module> parameter indicates the following:
MP – The active management module
STANDBY_MP – The standby management module
SNM – The switch fabric module
LP – An interface module
The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
NOTE: As indicated in
For Brocade internal use only.
For Brocade internal use only.
For Brocade internal use only.
Associations between show chassis, show fan threshold, and fan-threshold commands
show fan-threshold command output
(thermal block)
THERMAL_SENSOR_TEST_RULE_MP
THERMAL_SENSOR_TEST_RULE_STANDBY_MP fan-threshold mp
THERMAL_SENSOR_TEST_RULE_STANDBY_MP
_CPU
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM
THERMAL_SENSOR_TEST_RULE_SNM_G2
THERMAL_SENSOR_TEST_RULE_SNM_G2
THERMAL_SENSOR_TEST_RULE_SNM_G2
THERMAL_SENSOR_TEST_RULE_LP
Table 37
on page 236, the low fan speed for each
module does not have a default low temperature threshold value,
nor can you configure this value. The "-1" value that appears in the
Fan Speed Low field for each module is a Brocade internal value
only.
boundaries.Table 39
lists the associations between the
Brocade MLX Series and NetIron XMR Hardware Installation Guide
fan-threshold command
configuration
fan-threshold mp
fan-threshold mp-cpu
fan-threshold mp-cpu
fan-threshold switch-fabric
fan-threshold switch-fabric
fan-threshold switch-fabric
fan-threshold switch-fabric-g2
fan-threshold switch-fabric-g2
fan-threshold switch-fabric-g2
fan-threshold lp
53-1003821-01