1
Router modules
If you try to configure MPLS on a device that has NI MLX 8x10G -D modules installed, you will see
the following error message.
Brocade(config)# router mpls
The command can't be used when system contains -d class modules.
If you install an NI-MLX-10Gx8-D module in a device that is running MPLS, the NI-MLX-10Gx8-D
module boots in INTERACTIVE mode, and the following error message is displayed.
Brocade#
Module is inserted into slot 7
SYSLOG: May 28 16:22:35:<13>May 28 16:22:35 System: Module was inserted to slot 7
Module 7 is -d class, it can't work when router mpls is enabled.
Reset slot 7
SYSLOG: May 28 16:22:48 :<13>May 28 16:22:48 Module 7 is reset by mgmt (reason:
boot to interactive mode)
Power supply requirements for NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules
For power supply requirements for NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules, refer to
Chapter 8, "Hardware
24-port 1 Gbps Ethernet copper RJ45 interface module
The 24-port 1 Gbps Ethernet copper interface module is available in the following formats:
This module has 32 Mb of flash memory and contains 24 RJ45 physical ports, through which you
can connect your router to other network routers. BR-MLX-1GCx24-X-ML support s up to 512K IPv4
routes in hardware and BR-MLX-1GCx24-X version supports up to 1M IPv4 routes in hardware.
BR-MLX-1GCx24-X-ML does not include a software license, but can be upgraded to an X version
through a software license. Please contact Brocade to purchase the license upgrade.
NOTE
When you install BR-MLX-1GCx24-X modules, you must upgrade the software on all interface
modules and management modules to the appropriate software release. For more information on
the appropriate software release refer to the Hardware Installation Notes that shipped with the
modules.
NOTE
When you are replacing older modules with 24x1G modules, you must first delete the software
configuration for the older module. If you do not delete the old configuration, a configuration
mismatch will occur when you install the new module. This mismatch will be displayed in the results
of the show config command.
NOTE
The SNMP Management Information Base (MIB) uses the Interface Index (ifIndex) to assign a unique
value to each port on a module or slot. The number of indexes that can be assigned per module is
20, 40, or 64, depending on the number of ports on the module. When installing 24-port copper or
fiber interface modules, you must change the ifIndex allocation to 64 before you install the module,