Return To Factory Default; Communication Setup - Barco Event Master E2 Lite User Manual

Table of Contents

Advertisement

System Setup
check all Ethernet connections. After checking connections, if devices still report "Not Connected," use the
procedure "Communication setup", page 172.

7.4 Return to factory default

General
Prior to performing any setup procedures, it is recommended that you perform a factory reset — in order to
reset all input, output and source mappings to their default values.
Particularly for customers in the events and rental marketplace, this procedure guarantees that any previous
input setups and memory registers (e. g., those that may have been programmed by other users) are
completely cleared from system memory.
If you are continuing an event (for example, day two of a three-day event), you do not need to
perform a factory reset. However, if you do elect to perform a factory reset, ensure that you have
backed up your system. for details, please refer to the procedure "Backing up the system", page
174.
Prerequisite
Ensure that you are familiar with the Reset Menu. For details on all menus, please refer to chapter
"Restoring Factory Default Settings", page 62.
Restoring factory settings
To restore all default settings to the Event Master series processor, use the following procedure:
1.
Select Factory Reset from the Setup Menu.
The Factory Reset Menu appears.
2.
Select Factory Reset to reset the entire system to its factory default values. Remember that all data will be
lost.
or
Select Factory Reset, Save IP to reset the entire system to its factory default values, but retains the IP
address of the unit.
A prompt appears, asking if you want to clear all configurations.
3.
Press SEL.
The system turns off, then it reboots.

7.5 Communication setup

General
In this procedure, you will set up communication between the Event Master series processor and the local
network.
Prerequisite
Ensure that you are familiar with the Ethernet Menu. For details on this menu, please refer to chapter
"System menu > Ethernet", page 57.
Static IP or DHCP?
Use one of the following procedure to:
turn on the DHCP feature and query the DHCP server to obtain a valid IP address. A DHCP server must be
available on the local network.
or turn off the DHCP feature and set a static IP address for the Event Master series processor, along with a
subnet mask and gateway.
172
R5909934 /00