System Menu > Ethernet - Barco Event Master E2 Lite User Manual

Table of Contents

Advertisement

9.
Rename the settings.xml file to settings_backup.xml.
Make sure that you do not change the file extension.
10.
Copy and paste the entire EM folder from your desktop to the root directory of a FAT32-formatted USB
drive.
3.
Import the simulated configuration created offline to the live system:
1.
Insert the USB drive into the USB port on the front of a live Event Master processor.
The live processor must be the same type as the simulated processor. If your simulated processor is an E2
Lite, the live processor must be an E2 Lite; if your simulated processor was an S3–4K, your live processor
must be an S3–4K. The card setup on the simulated system must match the card setup on the live system,
otherwise Inputs might not match, or Destinations might be created on nonexistent Outputs. Those
Destinations will be grayed out, and you'll have to recreate them.
2.
Navigate on the front-panel display screen to the System menu, then to USB Backup/Restore, and then
to Restore XML, and then hit Select.
The system uploads the backup xml folder. When finished, the display screen reads "Restore successful."
3.
Select Yes (<SEL>), when the system asks "Reset unit now?"
The unit begins to reset. This takes about two minutes.
4.
Remove the USB drive.
Once the system resets, all the Inputs, Outputs, Destinations Presets, etc. from the simulated unit will have
been transferred to the live unit.
The icons from the simulated unit do not transfer to the live unit and must be recreated.
If the Multiviewer configurations are not transferred, they must be recreated.
5.9 System menu > Ethernet
General
The Ethernet submenu allows the user to view and change certain Ethernet settings.
Image 5-17
Using this menu, you can:
Query the DHCP server for a valid IP address, or turn off this feature.
Set a static IP address for the Event Master unit, along with a subnet mask and gateway. This feature is
available only if DHCP is turned Off.
View the unit's IP address.
If there is no internet connection, or if a DHCP server has not been found, the IP address is
000.000.000.000. In this case, the system ignores the Ethernet port.
View the Media Access Control (MAC) address of the unit's Ethernet port.
Query the DHCP server
In the Ethernet submenu, the default setting for DHCP is On. When DHCP is turned on, the system
automatically queries the DHCP server for a valid IP address. If the unit receives an IP address, that address
is displayed in the Ethernet submenu.
It can take several seconds to obtain an address from the server. During this time, the SEL button
remains lit.
When DHCP is off, you can manually enter a static IP address, along with a subnet mask and gateway, in the
Set Static IP submenu. Consult your network administrator for a valid IP address, subnet mask and gateway.