Omron OMNUC W Series Manual page 270

Devicenet option unit
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

No
Access
Name
126
Get/Set
Position 14 for
Multi-speed
127
Get/Set
Position 15 for
Multi-speed
128
Get/Set
Position 16 for
Multi-speed
129
Get/Set
Speed 1 for
Multi-speed
130
Get/Set
Speed 2 for
Multi-speed
131
Get/Set
Speed 3 for
Multi-speed
132
Get/Set
Speed 4 for
Multi-speed
133
Get/Set
Speed 5 for
Multi-speed
134
Get/Set
Speed 6 for
Multi-speed
135
Get/Set
Speed 7 for
Multi-speed
136
Get/Set
Speed 8 for
Multi-speed
137
Get/Set
Speed 9 for
Multi-speed
138
Get/Set
Speed 10 for
Multi-speed
139
Get/Set
Speed 11 for
Multi-speed
140
Get/Set
Speed 12 for
Multi-speed
141
Get/Set
Speed 13 for
Multi-speed
142
Get/Set
Speed 14 for
Multi-speed
143
Get/Set
Speed 15 for
Multi-speed
144
Get/Set
Speed 16 for
Multi-speed
160
Get/Set
Notch Signal Posi-
tion Designation
Data Type
Description
DINT
Sets speed-switching position 14 for multi-
speed.
Unit: Steps
DINT
Sets speed-switching position 15 for multi-
speed.
Unit: Steps
DINT
Sets speed-switching position 16 for multi-
speed.
Unit: Steps
DINT
Sets speed 1 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 2 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 3 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 4 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 5 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 6 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 7 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 8 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 9 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 10 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 11 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 12 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 13 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 14 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 15 for multi-speed.
×
Unit:
1000 steps/min
DINT
Sets speed 16 for multi-speed.
×
Unit:
1000 steps/min
USINT
Sets notch signal output position.
0: Specifies absolute position.
1: Specifies relative position.
10-13
10.2 DeviceNet Attributes
(cont'd)
Setting
Default
Range
Setting
0 to
0
99,999,999
0 to
0
99,999,999
0 to
0
99,999,999
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
1 to 240,000
24,000
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0 to
24,000
99,999,999
0, 1
0
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnuc w r88a-ncw152-drt

Table of Contents