A.F1
A.F1: Missing Phase Detected
Display and Outputs
Alarm Outputs
Alarm Code Outputs
ALO1
ALO2
OFF
ON
Note OFF: Output transistor is OFF (alarm state). ON: Output transistor is ON.
Status and Remedy for Alarm
At main circuit power
supply ON.
Cause
A
One phase (L1, L2, or L3) of the main cir-
cuit power supply is disconnected.
B
There is one phase where the line voltage is
low.
C
The Servo Driver is defective.
Note A and B tend to occur in a Servo Driver with a capacity of 500 W or higher.
9-41
9.3 Troubleshooting with Alarm Displays
ALM Output
ALO3
OFF
OFF
Occurred when the control
A B
circuit power turned ON.
• Check power supply.
• Check wiring of the main circuit power
supply.
• Check QF, noise filter, magnetic contac-
tor.
Check power supply.
Replace the Servo Driver.
C
Remedy