1 Features and System Configuration
1.4.1 General Specifications
1.4 Specifications
1.4.1 General Specifications
1
Applicable Servo Driver
Installation Method
Basic Specifica-
tions
Environment
This section shows the ratings and specifications of DeviceNet Unit.
The DeviceNet Unit provides the following general specifications.
Item
Power Supply Method
Power Consumption
External Dimensions [mm]
Approx. Mass [kg] (lb)
Current Consumption
Ambient Operating Temperature
Ambient Operating Humidity
Ambient Atmosphere
Ambient Storage Temperature
Ambient Storage Humidity
Vibration Resistance
Impact Resistance
* A DeviceNet Unit cannnot be used with software version 8.
R88D-WT
(software version 14 or later)*
Mounted on the CN10 connector on the Servo Driver side
Supplied from the control power supply of the Servo Driver.
1.3 W
×
×
×
20
142
128 (W
H
0.2 (0.441)
250 mA
°
0 to 55
C
90 % RH or less (non-condensing)
Free from corrosive gasses
°
-20 to 85
C
90 %RH or less (non-condensing)
2
4.9 m/s
2
Acceleration 19.6 m/s
three times in each X, Y, and Z direction)