Trace Setting Object (0X67) - Omron OMNUC W Series Manual

Devicenet option unit
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

10.2.9 Trace Setting Object (0x67)

Class and instances of the Trace Setting Object (0x67) are shown below.
Class
Instances
Attributes (Instance #1: Explicit Message)
No.
Access
Name
10
Get/Set
Data Trace 1
11
Get/Set
Data Trace 2
12
Get/Set
I/O Trace 1
13
Get/Set
I/O Trace 2
14
Get/Set
Sampling Cycle
15
Get/Set
Trigger Target
16
Get/Set
Trigger Level
17
Get/Set
Edge Type
18
Get/Set
Pre-trigger
19
Get/Set
Start Trace
20
Get
Trace State
• Attributes: None supported
• Services: None supported
Data Type
UINT
Specifies the data trace 1 target.
UINT
Specifies the data trace 2 target.
UINT
Specifies the I/O trace 1 target.
UINT
Specifies the I/O trace 2 target.
DINT
Specifies the sampling cycle.
µs
Unit:
UINT
Specifies the trigger condition.
UINT
Specifies the trigger level.
UINT
Specifies the edge type.
UINT
Specifies the amount of pre-trigger data.
UINT
Specifies the trace execution status.
0: No-operation (initial status)
1: Trace Start Command
2: Trace Stop Command
UINT
Stores the trace execution status.
0000 Hex: Initial status
0001 Hex: Tracing data.
0002 Hex: Trace completed.
0010 Hex: Trace interrupted.
0011 Hex: Setting error
10-25
Description
(Read enabled.)
10.2 DeviceNet Attributes
Setting
Default
Range
Setting
0 to 4
0
0 to 4
1
80 to 8D Hex
83 Hex
80 to 8D Hex
81 Hex
250 to
250
8191750
0 to 4
0
0000 to FFFF
0
Hex
0 to 2
0
0 to 999
0
0 to 2
0
0
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnuc w r88a-ncw152-drt

Table of Contents