Table 9.3 Troubleshooting Table with No Alarm Display (cont'd)
Symptom
Abnormal noise
Cause
Mechanical mounting is incorrect.
Bearing is defective.
Machine causing vibrations
9-45
9.4 Error Diagnosis Due To Operating Status
Inspection
Check if Servomotor
Tighten mounting screws.
mounting screws loose.
Check if coupling not cen-
Center coupling.
tered.
Check if coupling unbal-
Balance coupling.
anced.
Check noise and vibration
Remove the cause of problem
near bearing.
and repair.
Check for presence of for-
Remove the cause of problem
eign object, damage or
and repair.
deformation of movable
parts of machine.
Remedy