Omron OMNUC W Series Manual page 268

Devicenet option unit
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

No
Access
Name
59
Get/Set
JOG Unit Selection
60
Get/Set
JOG Speed
61
Get/Set
JOG Acceleration
Time
62
Get/Set
JOG Deceleration
Time
63
Get/Set
JOG Switch Speed
64
Get/Set
JOG Second Accel-
eration/Decelera-
tion Time
65
Get/Set
JOG Acceleration/
Deceleration Type
70
Get/Set
Time Constant
for Exponential
Curve
71
Get/Set
Bias Speed
72
Get/Set
Time Constant of
Moving Average
73
Get/Set
Maximum Speed
74
Get/Set
Step Distance1
75
Get/Set
Step Distance2
76
Get/Set
Step Distance3
77
Get/Set
Step Distance4
90
Get/Set
Positioning
Completion Range
91
Get/Set
Positioning
Monitor Time
92
Get/Set
Positioning Near
Range
93
Get/Set
Direction
Data Type
Description
UINT
Sets the command unit for the speed setting
for JOG.
DINT
Sets the JOG speed.
×
Unit:
1000 steps/min
UINT
Sets the JOG acceleration time.
Unit: ms
UINT
Sets the JOG deceleration time.
Unit: ms
DINT
Sets the switch speed for second accelera-
tion/deceleration for the JOG.
×
Unit:
1000 steps/min
UINT
Sets the acceleration/deceleration time for
the second acceleration/deceleration for the
JOG.
Unit: ms
UINT
Sets the JOG acceleration/deceleration
type.
0: None
1: Single-step linear
2: Double-step linear
3: Asymmetric
UINT
Sets the time constant of exponential accel-
eration/deceleration.
Unit: ms
DINT
Sets the bias speed of exponential accelera-
tion/deceleration with bias.
×
Unit:
1000 steps/min
UINT
Sets the time constant of moving average.
Unit: ms
DINT
Sets the maximum speed.
×
Unit:
1000 steps/min
DINT
Sets step distance 1 for STEP operation.
Unit: Steps
DINT
Sets step distance 2 for STEP operation.
Unit: Steps
DINT
Sets step distance 3 for STEP operation.
Unit: Steps
DINT
Sets step distance 4 for STEP operation.
Unit: Steps
UINT
Sets the positioning completion range.
Unit: Steps
UINT
Sets the positioning monitoring time.
Unit: ms
UINT
Sets the width for the positioning proximity
signal.
Unit: Steps
BOOL
Sets the direction of rotation for station
positioning.
10-11
10.2 DeviceNet Attributes
(cont'd)
Setting
Default
Range
Setting
0, 1
0
1 to 240,000
24,000
1 to 10,000
100
1 to 10,000
100
1 to 240,000
12,000
1 to 10,000
200
0 to 3
0
4 to 1,000
25
0 to 240,000
0
4 to 1,000
25
1 to 240,000
24,000
0 to
1
99,999,999
0 to
10
99,999,999
0 to
100
99,999,999
0 to
1,000
99,999,999
0 to 10,000
5
0 to 65535
0
0 to 32767
10
0, 1
0
10