Connection Object (0X05) - Omron OMNUC W Series Manual

Devicenet option unit
Hide thumbs Also See for OMNUC W Series:
Table of Contents

Advertisement

10.2.5 Connection Object (0x05)

Class and instances of the Connection Object (0x05) are shown below.
Class
• Attributes: None supported
• Services: None supported
Instances
Attributes (Instance #1: Explicit Message)
No
Access
Name
1
Get
State
2
Get
Instance_type
3
Get
TransportClass_
trigger
4
Get/Set
Produced_
Connection_ID
5
Get/Set
Consumed_
Connection_ID
6
Get/Set
Initial_Comm_
Characteristics
7
Get
Produced_
Connection_Size
8
Get
Consumed_
Connection_Size
9
Get/Set
Expected_
Packet_Rate
12
Get
Watchdog_
Timeout_Action
13
Get
Produced_
Connection_
Path_Length
14
Get
Produced_
Connection_Path
15
Get
Consumed_
Connection_
Path_Length
16
Get
Consumed_
Connection_Path
Data Type
Description
USINT
Defines the state of the object.
USINT
Defines either I/O or messaging connection.
Byte
Defines behavior of the connection.
UINT
Placed in CAN Identifier Field when the connec-
tion transmits
UINT
CAN Identifier Field value that denotes message
to be received
USINT
Defines the message group across which produc-
tions and consumption associated with this con-
nection occur.
UINT
Maximum number of bytes transmitted across
this connection
UINT
Maximum number of bytes received across this
connection
UINT
Defines timing associated with this connection.
USINT
Defines how to handle timeouts.
UINT
Number of bytes in the produced connection
path attribute
USINT
Specifies the application object whose data is to
Array
be sent by this connection object.
UINT
Number of bytes in the consumed connection
path attribute
USINT
Specifies the application object that are to
Array
receive the data received by this connection
object.
10-7
10.2 DeviceNet Attributes
Value
0x0000
0x83
0x21
0x00FF
0x00FF
0x03
0x0000
0x0000
10