Rtd.lo - Calibrating Minimum Resistance Value; Rtd.hi - Calibrating Maximum Resistance Value; Hour - Setting Hours; Min - Setting Minutes - gefran 850 Installation And Instruction Manual

Double pid temperature controller
Table of Contents

Advertisement

4.31.5. RTD.LO - Calibrating minimum resistance value

Acronym
RTD.LO
The parameter appears if you are calibrating a main input or custom RTD auxiliary input.
To calibrate:
apply a resistance corresponding to minimum scale value to the main input (for example, 18.52 Ω for Pt100) ;
press the
key to acquire the calibration value.
Unit of measurement:
Options:
-

4.31.6. RTD.HI - Calibrating maximum resistance value

Acronym
RTD.HI
The parameter appears if you are calibrating a main input or custom RTD auxiliary input.
To calibrate:
apply a resistance corresponding to maximum scale value to the main input (for example, 390.48 Ω for Pt100);
press the
key to acquire the calibration value.
Unit of measurement:
Options:
-

4.31.7. HOUR - Setting hours

Acronym
HOUR
The parameter shows and sets the hours on the Real Time Clock, if U.CAL = RTC.
Unit of measurement:
Options:
0...23

4.31.8. MIN - Setting minutes

Acronym
MIN
The parameter shows and sets the minutes on the Real Time Clock, if U.CAL = RTC.
Unit of measurement:
Options:
0...59

4.31.9. SEC - Setting seconds

Acronym
SEC
The parameter shows and sets the seconds on the Real Time Clock, if U.CAL = RTC.
Unit of measurement:
Options:
0...59
Scrolling message
-
Scrolling message
-
Scrolling message
Ore
Scrolling message
Minutes
Scrolling message
Seconds
80209C_MHW_850-1650-1850_02-2020_ENG_pag. 190