5.13.5.3. Program with assigned events

Project conditions:
Evnt.1 On during STEP1;
Evnt.2 On during hold of STEP1;
Evnt.3 On during ramp of STEP2;
Evnt.4 not used.
STEP1 - setting events at start of step:
EVN.r.1 = On
EVN.r.2 = OFF
EVN.r.3 = OFF
EVN.r.4 = nonE
STEP1 - setting events at start of hold:
EVN.h.1 = nonE
EVN.h.2 = On
EVN.h.3 = nonE
STEP2 - setting events at start of step:
EVN.r.1 = OFF
EVN.r.2 = OFF
EVN.r.3 = On
EVN.r.4 = nonE
STEP2 - setting events at start of hold:
EVN.h.1 = nonE
EVN.h.2 = nonE
EVN.h.3 = OFF
EVN.h.4 = nonE
SP
Set
point
t1
t2
Soak time
t1 + t2 = Ramp time
STEP 1
RUN
PRG
END
PRG
EV1
EV2
EV3
EV4
Using GF_eXpress software for the configuration, the di-
splayed pages would be:
Wait band
Wait band
PV
time
Ramp
END
Soak time
time
STEP 2
80209C_MHW_850-1650-1850_01-2020_ENG_pag. 213
Program diagram
Configuration of STEP1