4.22.9. MUL.SP - Enabling Multiset function

Acronym
MUL.SP
MODE.1 (o MODE.2) MULTISET ENABLE
The parameter shows and sets enabling of the Multiset function.
The MULTISET function is explained in detail in paragraph "5.12. Multiset, setpoint gradient" on page <?>.
Unit of measurement:
Options:
OFF
On

4.22.10. SP.REM - Enabling the remote setpoint

Acronym
SP.REM
MODE.1 (o MODE.2) REMOTE SP ENABLE
The parameter shows and sets enabling of the remote setpoint.
Unit of measurement:
Options:
OFF
On
SEr

4.22.11. SPR.T - Defining absolute or deviation remote setpoint

Acronym
SPr.t
MODE.1 (o MODE.2) REMOTE SP TYPE
The parameter shows and defines the setpoint as absolute or deviation.
The absolute remote setpoint replaces the local setpoint in the control.
The deviation remote setpoint is added algebraically to the local setpoint in the control.
The parameter appears only if the parameter SP.REM is different from OFF
Unit of measurement:
Options:
ABSLT = Absolute remote setpoint
RELAT = Deviation remote setpoint

4.22.12. T.PRO - Setting the programmer base time

Acronym
t.Pro
MODE.1 (o MODE.2) PROGRAMMER BASE TIME DEFINITION
The parameter shows and sets the base time used by the programmer.
The parameter appears if the parameter PROGR = On.
Unit of measurement:
Options:
HH.MM = Base time calculated in hours:minutes
MM.SS = e time calculated in minutes:seconds

4.22.13. ENERG - Enabling the energy counter function

Acronym
ENERG
MODE.1 (o MODE.2) ENERGY COUNTER ENABLE
The parameter shows and sets enabling of the energy counter function.
The Energy Counter function is explained in detail in paragraph "5.15. Energy counter" on page <?>.
Unit of measurement:
Options:
OFF
On
Scrolling message
-
= Multiset disabled
= Multiset enabled
Scrolling message
-
= Remote setpoint disabled
= Remote setpoint enabled from analog input
= Remote setpoint enabled from serial
Scrolling message
-
Scrolling message
-
Scrolling message
-
= Energy counter disabled
= Energy counter enabled
80209C_MHW_850-1650-1850_02-2020_ENG_pag. 154
Submenu
Attributes
MODE
R W
Submenu
Attributes
MODE
R W
Submenu
Attributes
MODE
R W
Submenu
Attributes
MODE
R W
Submenu
Attributes
MODE
R W