4.8.10. HBB.R - Enabling HBB during ramp
Acronym
HBB.R
PR.STP.1 (o PR.STP.2...PR.STP.192) ENABLE HOLD BACK BAND DURING
STEP RAMP se modalità"Programmatore semplificato"disattiva; o PR.STP.1...
PR.STP.16 ENABLE HOLD BACK BAND DURING STEP RAMP se modalità
"Programmatore semplificato"attiva.
If the HBB function is enabled, the parameter enables and disables it during the step ramp time.
Unit of measurement:
Options:
OFF
On
4.8.11. HBB.H - Enabling HBB during hold
Acronym
HBB.H
PR.STP.1 (o PR.STP.2...PR.STP.192) ENABLE HOLD BACK BAND DURING
STEP HOLD se modalità"Programmatore semplificato"disattiva; o PR.STP.1...
PR.STP.16 ENABLE HOLD BACK BAND DURING STEP HOLD se modali-
tà"Programmatore semplificato"attiva.
If the HBB function is enabled, the parameter enables and disables it during the step ramp time.
Unit of measurement:
Options:
OFF
On
4.8.12. HBB2 - Enabling HBB with respect to the auxiliary input
Acronym
HBB2
PR.STP.1 (o PR.STP.2...PR.STP.192) HOLD BACK BAND FUNCTION
REFERRED TO AUX INP se modalità"Programmatore semplificato"disattiva;
o PR.STP.1...PR.STP.16 HOLD BACK BAND FUNCTION REFERRED TO AUX
INP se modalità"Programmatore semplificato"attiva.
If the HBB function is enabled, the parameter enables and disables it with respect to the remote setpoint input, which can
be enabled on the MODE submenu, SP.REM parameter = On
When the function is enabled with respect to the auxiliary input, if deviation PV1-IN2 exceeds BAND value, the program's
time base is blocked.
The parameter is significant only if the step pertaining to PROGR.1 with optional auxiliary input is present and PID.2 and
PROGR.2 are not enabled (parameter PID2.E=OFF and PROGR=On1 on EN.FUN submenu).
Unit of measurement:
Options:
OFF
On
4.8.13. S.SP.EN - Enabling retransmission of setpoint to analog output
Acronym
S.SP.EN
PR.STP.1 (o PR.STP.2...PR.STP.192) SUBDUED SETPOINT RETRANSMITTED
ENABLE se modalità"Programmatore semplificato"disattiva; o PR.STP.1...PR.
STP.16 SUBDUED SETPOINT RETRANSMITTED ENABLE se modalità"Prog-
rammatore semplificato"attiva.
The parameter enables and disables retransmission of the setpoint value to other slaved controllers.
The setpoint value is transmitted by analog output A1 or A2 if configured on submenu OUT.AN, parameter Func=SLV.S1
or Func=SLV.S2.
Unit of measurement:
Options:
OFF
On
Scrolling message
-
= Disables HBB function during ramp time
= Enables HBB function during ramp time
Scrolling message
-
= Disables HBB function during ramp time
= Enables HBB function during ramp time
Scrolling message
-
= Disables HBB function with respect to remote setpoint input
= Enables HBB function with respect to remote setpoint input
Scrolling message
-
= Disables retransmission
= Enables retransmission