Rese - Selecting The Reset Timer Command; Res.t - Defining The Timer Reset Command Logic; Band - Band For Timer Count; End - Selecting The Function Activated At End Of Count - gefran 850 Installation And Instruction Manual

Double pid temperature controller
Table of Contents

Advertisement

4.23.6. RESE - Selecting the Reset timer command

Acronym
rESE
TIMER.1 (o TIMER.2) TIMER RESET
The parameter shows and sets the "object" that commands Reset of the timer
Unit of measurement:
Options:
AUT.RS = For autoreset with timer in Stop
IN.DIG = From digital input with T.RST function
ALRM1 = From alarm 1
ALRM2 = From alarm 2
ALRM3 = From alarm 3
ALRM4 = From alarm 4
AL.HB
SERIA

4.23.7. RES.T - Defining the timer reset command logic

Acronym
rES.t
TIMER.1 (o TIMER.2) LOGIC TYPE OF TIMER RESET
The parameter shows and sets the type of logic used to command the timer reset.
With positive logic, the timer is reset with "object" active.
With negative logic, the timer is reset with "object" inactive.
Unit of measurement:
Options:
POSIT
NEGAT = Negative logic

4.23.8. BAND - Band for timer count

Acronym
BAND
TIMER.1 (o TIMER.2) SYMM SP BAND WHERE TIMER IS ACTIVE
The parameter shows and sets the symmetrical band around the setpoint within which the timer count is on.
The parameter appears if the parameter F.tiM = STABL
If the parameter equals "0.0" the count is immediate as soon as the setpoint is reached for the first time.
Unit of measurement:
Options:
0.0...25.0

4.23.9. END - Selecting the function activated at end of count

Acronym
End
TIMER.1 (o TIMER.2) FUNCTION WHERE TIMER IS OVER
The parameter shows and sets the function that is activated when the timer ends the count.
The parameter appears if the parameter F.tiM = ST.STP or STABL.
Unit of measurement:
Options:
NONE
OFF
if the Multiset function is enabled:
SP1-2
Scrolling message
-
= From alarm HB
= From serial
Scrolling message
-
= Positive logic
Scrolling message
% of full scale of main or auxiliary input
Scrolling message
-
= None: control continues with actual setpoint
= Software off
= Change setpoint SP1/SP2
80209C_MHW_850-1650-1850_02-2020_ENG_pag. 158
Submenu
Attributes
TIMER
R W
Submenu
Attributes
TIMER
R W
Submenu
Attributes
TIMER
R W
Submenu
Attributes
TIMER
R W